Pathological Effects of Extensive Radiofrequency Energy Applications in the Pulmonary Veins in Dogs

Author:

Taylor Gregg W.1,Kay G. Neal1,Zheng Xiangsheng1,Bishop Sanford1,Ideker Raymond E.1

Affiliation:

1. From the Department of Medicine, Division of Cardiovascular Diseases, and the Department of Pathology (S.B.), University of Alabama at Birmingham.

Abstract

Introduction —The long-term complications of catheter ablation within the pulmonary veins are unknown. The development of pulmonary vein stenosis has recently been described after catheter ablation to treat either chronic or paroxysmal atrial fibrillation. The purpose of this study was to examine the pathological and hemodynamic effects of radiofrequency (RF) energy application within the pulmonary veins. Methods and Results —Right heart and transseptal catheterization were performed in 9 anesthetized mongrel dogs. The pulmonary vein ostia were cannulated and pulmonary venous pressure was measured before RF energy application in up to 4 separate pulmonary veins. Animals were euthanized at intervals of 2 to 4 weeks (n=3), 6 to 8 weeks (n=3), or 10 to 14 weeks (n=3) after ablation. Repeat catheterization before euthanasia demonstrated statistically significant differences in pulmonary capillary wedge pressure, cardiac output, pulmonary vascular resistance, and systemic vascular resistance ( P <0.05) compared with the baseline. Luminal narrowing was observed in 22 of 33 pulmonary veins to which RF energy was applied. Of these, 7 were totally occluded, 7 had severe stenosis, and 8 were only minimally narrowed. Histological examination revealed intimal proliferation with organizing thrombus, necrotic myocardium in various stages of collagen replacement, endovascular contraction, and a proliferation of elastic lamina. Conclusions —Applications of RF current within the pulmonary veins may result in pulmonary vein narrowing or complete occlusion. These observations should be considered in treatment of arrhythmias originating within the pulmonary veins.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3