Coronary Pressure Measurement to Assess the Hemodynamic Significance of Serial Stenoses Within One Coronary Artery

Author:

Pijls Nico H.J.1,De Bruyne Bernard1,Bech G. Jan Willem1,Liistro Francesco1,Heyndrickx Guy R.1,Bonnier Hans J.R.M.1,Koolen Jacques J.1

Affiliation:

1. From the Department of Cardiology, Catharina Hospital (N.H.J.P., G.J.W.B., F.L., H.J.R.M.B, J.J.K.), and the Department of Biomedical Engineering, Eindhoven University of Technology (N.H.J.P.), Eindhoven, The Netherlands, and the Department of Cardiology, Cardiovascular Center Aalst, Belgium (B.D.B., G.R.H.).

Abstract

Background —When several stenoses are present within 1 coronary artery, the hemodynamic significance of each stenosis is influenced by the presence of the other(s), and the calculation of coronary and fractional flow reserve (CFR and FFR) for each individual stenosis is confounded. Recently, we developed and experimentally validated a method to determine the true FFR of each stenosis as it would be after the removal of the other stenosis; the true FFR can be reliably predicted by coronary pressures measured before treatment at specific locations within the coronary artery using equations accounting for stenosis interaction. The aim of the present study was to test the validity of these equations in humans. Methods and Results —In this study of 32 patients with 2 serial stenoses in 1 coronary artery, relevant pressures were measured before the intervention, after the treatment of 1 stenosis, and after the treatment of both stenoses. The true FFR of each stenosis (FFR true ) was directly measured after the elimination of the other stenosis and compared with the value predicted (FFR pred ) from the initial pressure measurements before treatment. Although the hyperemic gradient across 1 stenosis increased significantly (from 10±7 to 19±11 mm Hg after treatment of the other stenosis), FFR pred was close to FFR true in all patients (0.78±0.12 versus 0.78±0.11 mm Hg; r =0.92; Δ%=4±0%). Without accounting for stenosis interaction, the value of FFR for each stenosis would have been significantly overestimated (0.85±0.08; P <0.01). Conclusions —Coronary pressure measurements made by a pressure wire at maximum hyperemia provide a simple, practical method for assessing the individual hemodynamic significance of multiple stenoses within the same artery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3