Electrical Remodeling of the Atria Following Loss of Atrioventricular Synchrony

Author:

Sparks Paul B.1,Mond Harry G.1,Vohra Jitendra K.1,Jayaprakash Shenthar1,Kalman Jonathan M.1

Affiliation:

1. From The Department of Cardiology, The Royal Melbourne Hospital (P.B.S., H.G.M., J.K.V., S.J., J.M.K.), and The Department of Medicine, University of Melbourne (P.B.S., J.M.K.), Melbourne, Australia.

Abstract

Background —Evidence suggests that an increased incidence of atrial fibrillation occurs in patients undergoing single-chamber ventricular pacing (VVI) when compared with those undergoing single-chamber atrial pacing (AAI) or those having dual-chamber atrioventricular pacing (DDD). The mechanism for this is unknown. We hypothesized that long-term loss of atrioventricular (AV) synchrony leads to atrial electrical remodeling: a potential explanation for this difference. Methods and Results —The study was a prospective, randomized comparison between 18 patients paced in VVI mode and 12 patients paced in DDD mode for 3 months. Under autonomic blockade, effective refractory periods (ERPs) from the lateral right atrium (RA), RA appendage, RA septum, and coronary sinus–corrected sinus node recovery times (cSNRTs), as well as P-wave duration (PWD), and biatrial diameters were measured at baseline and 3 months. The VVI group was then programmed to DDD pacing and reevaluated after a further 3 months. After long-term VVI pacing, ERPs at all 4 atrial sites increased significantly in a nonuniform fashion in association with biatrial dilatation. PWD and cSNRTs also prolonged significantly. With the reestablishment of AV synchrony, ERPs, PWD, cSNRTs, and biatrial dimensions returned to baseline levels. In the 12 patients who underwent long-term DDD pacing from baseline, no significant changes in atrial electrophysiology or biatrial dimensions were demonstrated. Conclusions —Long-term loss of AV synchrony induced by VVI pacing is associated with atrial electrical remodeling, which is reversible after the reestablishment of AV synchrony with DDD pacing. This process may be partly responsible for the higher incidence of atrial fibrillation in patients undergoing VVI pacing compared with AV sequential pacing.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3