Abstract

Background —We evaluated the ability of electromechanical mapping of the left ventricle to distinguish between nonviable and viable myocardium in patients with ischemic cardiomyopathy. Methods and Results —Unipolar voltage amplitudes and local endocardial shortening were measured in 31 patients (mean±SD age, 62±8 years) with ischemic cardiomyopathy (ejection fraction, 30±9%). Dysfunctional regions, identified by 3D echocardiography, were characterized as nonviable when PET revealed matched reduction of perfusion and metabolism and as viable when perfusion was reduced or normal and metabolism was preserved. Mean unipolar voltage amplitudes and local shortening differed among normal, nonviable, and viable dysfunctional segments. Coefficient of variation for local shortening exceeded differences between groups and did not allow distinction between normal and dysfunctional myocardium. Optimum nominal discriminatory unipolar voltage amplitude between nonviable and viable dysfunctional myocardium was 6.5 mV, but we observed a great overlap between groups. Individual cutoff levels calculated as a percentage of electrical activity in normal segments were more accurate in the detection of viable dysfunctional myocardium than a general nominal cutoff level. The optimum normalized discriminatory value was 68%. Sensitivity and specificity were 78% for the normalized discriminatory value compared with 69% for the nominal value ( P <0.02). Conclusions —Endocardial ECG amplitudes in patients with ischemic cardiomyopathy display a wide scatter, complicating the establishment of exact nominal values that allow distinction between viable and nonviable areas. Individual normalization of unipolar voltage amplitudes improves diagnostic accuracy. Electroanatomic mapping may enable identification of myocardial viability.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3