Influence of the Sympathetic System on the Pacemaker Suppression Which Follows Overdrive

Author:

PLIAM MICHAEL B.1,KRELLENSTEIN DANIEL J.1,VASSALLE MARIO1,BROOKS CHANDLER McC.1

Affiliation:

1. From the Department of Physiology, State University of New York Downstate Medical Center, Brooklyn, New York.

Abstract

When ventricular pacemakers are electrically stimulated at a fast rate, the cessation of the drive is followed by a temporary suppression of automaticity ("overdrive suppression"). The role of the sympathetic system in the regulation of this overdrive suppression was studied and the following results obtained: 1) Hypotension induced during overdrive by amyl nitrite inhalation caused a shortening of the pause which follows the drive. 2) Bilateral resection of the stellate ganglia led to the opposite effect. 3) Maximal stellate ganglion stimulation halved the pause duration. 4) Norepinephrine infusion accelerated the idioventricular rate and shortened the pause. 5) Beta adrenergic blockade decreased the idioventricular rate and prolonged the pause. It is concluded that the tonic sympathetic discharge not only controls the basal idioventricular rate but also plays a regulatory role in the suppression of idioventricular automaticity which follows overdrive. This regulatory role can be dissociated from changes in idioventricular rate prior to overdrive.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference30 articles.

1. Factors controlling pacemaker action in cells of the sinoatrial node;Circ Res,1964

2. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@24587abe : Effects of chronotropic influences on subthreshold oscillations in the sinoatrial node. In Specialized Tissues of the Heart edited by A Paes de Carvalho WC de Mello BF Hoffman New York Elsevier Publishing Co 1961 p 81

3. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@615ae051 : Ventricular slowing and standstill after spontaneous or electrically stimulated runs of rapid ventricular beats in atrioventricular block. (abstr) Circulation 22: 781 1960

4. Correction of complete heart block by a self-contained and subcutaneously implanted pacemaker;J Thoracic Cardiovasc Surg,1961

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3