Long‐Term Results of Congenital Aortic Stenosis Treatment in the Era of Percutaneous Balloon Valvuloplasty: Up to 33 Years Follow‐Up

Author:

Materna Ondřej1ORCID,Tax Petr1,Tomek Viktor1ORCID,Koubský Karel1ORCID,Chaloupecký Václav1ORCID,Janoušek Jan1,Reich Oleg1

Affiliation:

1. Children’s Heart Centre 2nd Faculty of Medicine, Charles University and Motol University Hospital Prague Czech Republic

Abstract

Background The goal of this study was to evaluate long‐term results of percutaneous balloon valvuloplasty (BVPL) used exclusively for initial management of congenital aortic stenosis in children. Methods and Results A total of 409 consecutive pediatric patients (134 newborns, 275 older patients) who underwent BVPL as initial treatment of aortic stenosis in a single nationwide pediatric center were subjected to a retrospective follow‐up study. The resulting follow‐up time reached a median of 18.5 (interquartile range, 12.2–25.1) years. Successful BVPL was defined by residual Doppler gradient <70/40 (systolic/mean) mm Hg. The primary end point was death; secondary end points included any valve reintervention, balloon revalvuloplasty, any aortic valve surgery, and aortic valve replacement, respectively. BVPL effectively reduced the peak and mean gradient both immediately and at the latest follow‐up ( P <0.001). There was significant procedure‐related progression of aortic insufficiency ( P <0.001). Higher aortic annulus z score was predictive for severe aortic regurgitation ( P <0.05) and lower z score for insufficient gradient reduction ( P <0.05). The actuarial probability of survival/survival free from any valve reintervention was 89.9%/59.9%, 85.9%/35.2%, and 82.0%/26.7% at 10, 20, and 30 years after first BVPL, respectively. Left ventricular dysfunction or arterial duct dependency as the indication for BVPL was predictive of both worse survival and survival free from any reintervention ( P <0.001). Lower aortic annulus z score and lower balloon‐to‐annulus ratio were predictive of a need for revalvuloplasty ( P <0.001). Conclusions Percutaneous BVPL provides good initial palliation. In patients with hypoplastic annuli and left ventricular or mitral valve comorbidity, the results are less favorable.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3