Feasibility, Safety, and Short‐Term Outcomes of Transcatheter Patent Ductus Arteriosus Closure in Premature Infants on High‐Frequency Jet Ventilation

Author:

Shibbani Kamel1ORCID,Mohammad Nijres Bassel1ORCID,McLennan Daniel1ORCID,Bischoff Adrianne Rahde2ORCID,Giesinger Regan2ORCID,McNamara Patrick J.12ORCID,Klein Jonathan2ORCID,Windsor Jimmy3ORCID,Aldoss Osamah1ORCID

Affiliation:

1. Division of Pediatric Cardiology Stead Family Children’s Hospital University of Iowa Iowa City IA

2. Division of Neonatology Stead Family Children’s Hospital University of Iowa Iowa City IA

3. Division of Pediatric Anesthesia University of Iowa Carver College of Medicine Iowa City IA

Abstract

Background Prolonged exposure to a hemodynamically significant patent ductus arteriosus (PDA) is associated with major morbidity, particularly in infants born at <27 weeks’ gestation. High‐frequency jet ventilation (HFJV) is a standard of care at our center. There are no data about transcatheter PDA closure while on HFJV. The aim of this study was to assess the feasibility, safety, and outcomes of HFJV during transcatheter PDA closure. Methods and Results This is a retrospective cohort study of premature infants undergoing transcatheter device closure on HFJV. The primary outcome was successful device placement. Secondary outcomes included procedure time, fluoroscopy time and dose, time off unit, device complications, need for escalation in respiratory support, and 7‐day survival. Subgroup comparative evaluation of patients managed with HFJV versus a small cohort of patients managed with conventional mechanical ventilation was performed. Thirty‐eight patients were included in the study. Median age and median weight at PDA device closure for the HFJV cohort were 32 days (interquartile range, 25.25–42.0 days) and 1115 g (interquartile range, 885–1310 g), respectively. There was successful device placement in 100% of patients. There were no device complications noted. The time off unit and the procedure time were not significantly different between the HFJV group and the conventional ventilation group. Infants managed by HFJV had shorter median fluoroscopy times (4.5 versus 6.1 minutes; P <0.05) and no increased risk of adverse respiratory outcomes. Conclusions Transcatheter PDA closure in premature infants on HFJV is a safe and effective approach that does not compromise device placement success rate and does not lead to secondary complications.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3