Standardization of Carotid Ultrasound

Author:

Ranke Carsten1,Creutzig Andreas1,Becker Hartmut1,Trappe Hans-Joachim1

Affiliation:

1. From the Department of Cardiology and Angiology, University Hospital Herne, Ruhr-University Bochum (C.R., H.-J.T.), Herne, Germany, and the Center of Internal Medicine, Department of Angiology (A.C.), and the Center of Radiology, Department of Neuroradiology (H.B.), Hannover Medical School, Hannover, Germany.

Abstract

Background and Purpose —Accurate carotid Doppler examination is an important issue in the light of large endarterectomy trials, but recommended cutoff values for detection of >70% stenosis vary widely. Standardization of diagnostic criteria should consider patient variation and instrument variability. Methods —We prospectively analyzed various Doppler parameters in 44 patients undergoing carotid angiography to evaluate whether normalization through individual reference measurements from the common carotid artery or the distal internal carotid artery could improve accuracy. For assessment of interindividual and interequipment variability, we performed repeated measurements of 40 carotid arteries in 21 patients. Two color-coded duplex ultrasound systems were compared for machine variability estimation: Hewlett Packard SONOS 2500 and ATL Ultramark 9 HDI. Results —Intrastenotic divided by distally recorded mean blood flow velocity (mean velocity ratio) showed the closest correlation with angiography: R 2 =0.93. Mean velocity ratio >5 was 97% sensitive and 98% specific for detection of >70% carotid stenosis. Intrastenotic blood flow velocities were significantly different between the 2 duplex systems (0.22±0.16 versus 0.17±0.11 m/s; P <0.001), whereas mean velocity ratio values did not differ significantly. Interobserver variation expressed as 95% CI for predicted stenosis between 2 observers was 13.6% (peak systolic velocity) and 15.4% (mean velocity ratio). Conclusions —A mean velocity ratio using distal reference measurement in the internal carotid artery can normalize for interindividual and interequipment variability.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3