Background and Purpose The purpose of this study was to assess the ultrasonic imaging of normal rabbit brain by using echocontrast enhancer to identify the brain tissue perfusion. Methods A solution of SH/TA-508 (containing microbubbles of mean size 2 to 4 μm; n=4) was used for contrast enhancement of rabbit brain tissue and was administered through the left internal carotid artery. Contrast enhancement in the ipsilateral parietal area was examined by placing a 7.5-MHz transducer on the dura after a craniectomy. Throughout the experiment, we measured parameters including arterial blood pressure, arterial blood gases, and serum glucose and hematocrit levels. We investigated whether the administration of an echocontrast enhancer would be safe for the brain tissue (n=4). Results After injection of 100 mg/mL SH/TA-508, contrast enhancement was clearly observed within approximately 1 second in the left hemisphere (especially in the left cerebral cortex) in all animals and disappeared within 3 seconds after the end of injection. All physiological parameters remained within the normal range throughout the experiment. No focal abnormalities were observed on hematoxylin-eosin staining of the brain tissue. Conclusions Contrast enhancement was observed in the ipsilateral hemisphere with the administration of SH/TA-508. Contrast enhancement on B-mode brain imaging would be useful for real-time identification of brain tissue perfusion and should become a promising method for bedside clinical assessment of brain tissue perfusion.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Reference17 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3