Transcranial Doppler Ultrasound Criteria for Hemodynamically Significant Internal Carotid Artery Stenosis Based on Residual Lumen Diameter Calculated From En Bloc Endarterectomy Specimens

Author:

Can Ufuk1,Furie Karen L.1,Suwanwela Nijasri1,Southern James F.1,Macdonald Nancy R.1,Ogilvy Christopher S.1,Buonanno Ferdinando S.1,Koroshetz Walter J.1,Kistler J. Philip1

Affiliation:

1. From the Stroke Service, Neurology Service (U.C., K.L.F., N.S., F.S.B., W.J.K., J.P.K.); the Department of Pathology (J.F.S.); the Vascular Laboratory (N.R.M.); and the Neurosurgery Service (C.S.O.), Massachusetts General Hospital, Boston, Mass.

Abstract

Background and Purpose Transcranial Doppler (TCD) is often used in conjunction with carotid duplex ultrasonography (CDUS) to evaluate the hemodynamic significance of internal carotid artery (ICA) stenosis. We examined the sensitivity and specificity of TCD criteria for detection of a hemodynamically significant stenosis (residual lumen diameter <1.5 mm) at the origin of the ICA. Methods We selected patients who underwent carotid endarterectomy (CEA) and had preoperative TCD data available. Eighty-one patients underwent transorbital evaluation, 49 of whom also had transtemporal TCD performed. The endarterectomy specimens were removed en bloc and sectioned, and the minimal residual lumen diameter calculated by computer analysis. Results For the transorbital approach, the strongest indicators of a residual lumen diameter <1.5 mm were reversed flow in the ipsilateral ophthalmic artery and a >50% peak systolic velocity difference between the carotid siphons (distal ICAs) in patients with unilateral ICA origin stenosis. They were 100% specific and 31% and 26% sensitive, respectively. For the transtemporal approach in patients with a unilateral stenosis, a >35% difference in ipsilateral middle cerebral artery (MCA) peak systolic velocity relative to the contralateral MCA or a >50% difference in contralateral anterior cerebral artery (ACA) peak systolic velocity relative to the ipsilateral ACA were 100% specific for identifying a residual lumen diameter of <1.5 mm. Sensitivities were 32% and 43%, respectively. Irrespective of contralateral stenosis, a >35% difference in ipsilateral MCA peak systolic velocity relative to the ipsilateral posterior cerebral artery had a 100% specificity and a 23% sensitivity for detecting a <1.5 mm minimal residual lumen diameter. Conclusions Although the TCD sensitivity for detecting a hemodynamically significant stenosis is relatively low, it can be highly specific (up to 100%). We conclude that TCD enhances the specificity of highly sensitive CDUS criteria for detecting a hemodynamically significant ICA stenosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3