Noninvasive assessment of cerebral collateral blood supply through the ophthalmic artery.

Author:

Schneider P A1,Rossman M E1,Bernstein E F1,Ringelstein E B1,Otis S M1

Affiliation:

1. Division of Vascular and Thoracic Surgery, Scripps Clinic and Research Foundation, La Jolla, Calif. 92037.

Abstract

We assessed the potential of 2-MHz pulsed-wave transorbital Doppler ultrasonography to delineate the role of the ophthalmic artery as a source of collateral cerebral blood supply by comparing oculopneumoplethysmography, transorbital Doppler ultrasonography, periorbital continuous-wave Doppler ultrasonography, and transcranial Doppler ultrasonography in 25 patients with unilateral internal carotid artery occlusion and five controls with 10 normal internal carotid arteries. Systolic ophthalmic artery blood velocity was reduced ipsilateral to an internal carotid artery occlusion (38.2 +/- 10.2 cm/sec) compared with the contralateral and control velocities (46.0 +/- 10.3 and 47.5 +/- 6.8 cm/sec, respectively; p less than 0.05). Ophthalmic systolic pressure measured by oculopneumoplethysmography was 94.7 +/- 13.2 mm Hg ipsilateral to an internal carotid artery occlusion compared with 108.4 +/- 15.3 mm Hg on the contralateral side (p less than 0.01). Transorbital and periorbital Doppler ultrasonography detected reversed ophthalmic artery blood flow ipsilateral to an internal carotid artery occlusion in 44.0% and 40.0% of the patients, respectively. Systolic middle cerebral artery blood velocity was 55.2 +/- 22.3 cm/sec ipsilateral to an internal carotid artery occlusion compared with 79.4 +/- 23.5 cm/sec on the contralateral side (p less than 0.05) and 101.2 +/- 18.9 cm/sec in the controls (p less than 0.05). Reversed ophthalmic artery blood flow was associated with a low middle cerebral artery blood velocity and lack of major intracerebral collaterals. Transorbital Doppler ultrasonography permits noninvasive evaluation of the ophthalmic artery.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Reference18 articles.

1. Measurement of collateral cerebral hemispheric blood pressure by ocular pneumoplethysmography;Gee W;Am J Surg,1975

2. Simultaneous bilateral determination of the systolic pressure of the ophthalmic arteries by ocular pneumoplethysmography;Gee W;Invest Ophthal Visual Sci,1977

3. Screening for significant carotid stenosis by ocular pneumoplethysmography

4. Aaslid R Markwalder TM Nornes H: Noninvasive transcranial Doppler ultrasound recording of flow velocity in the basal cerebral arteries. / Neurosurg 1982;57:769-774

5. Transcranial Dopplersonography. Examination technique and normal reference values

Cited by 65 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3