Carotid Doppler Ultrasound Criteria for Internal Carotid Artery Stenosis Based on Residual Lumen Diameter Calculated From En Bloc Carotid Endarterectomy Specimens

Author:

Suwanwela Nijasri1,Can Ufuk1,Furie Karen L.1,Southern James F.1,Macdonald Nancy R.1,Ogilvy Christopher S.1,Hansen Calvin J.1,Buonanno Ferdinando S.1,Abbott William M.1,Koroshetz Walter J.1,Kistler J. Philip1

Affiliation:

1. the Stroke Service, Neurology Service (N.S., U.C., K.L.F., C.J.H., F.S.B., W.J.K., J.P.K.), Neurosurgery Service (C.S.O), Vascular Laboratory (N.R.M.), Vascular Surgery Service (W.M.A.), and Pathology Service (J.F.S.), Massachusetts General Hospital, Boston, Mass.

Abstract

Background and Purpose Carotid duplex ultrasound is widely used to screen patients for carotid endarterectomy and if combined with MR angiography and transcranial Doppler may be an alternative to conventional angiography in the preoperative assessment. We have examined the correlation between Doppler velocities and the residual lumen diameters of internal carotid arteries from surgical pathological specimens to establish Doppler criteria for residual lumen diameter independent of percent stenosis. Methods Ninety-one patients who underwent 99 carotid endarterectomies for internal carotid artery stenosis within 6 months of their carotid duplex ultrasound evaluation were studied. The endarterectomy specimens were removed en bloc, and the minimal residual lumen diameter was calculated by computer analysis. The sensitivity and specificity of the Doppler criteria for determining high-grade stenosis were calculated and receiver-operator curves generated. Results Peak systolic velocity (PSV), end-diastolic velocity (EDV), and carotid index (peak internal carotid artery velocity/common carotid artery velocity) correlated with the residual lumen diameter. PSV >440 cm/s, EDV >155 cm/s, or carotid index >10 indicated a residual lumen diameter of ≤1.5 mm (specificity of 100% and sensitivity of 58%, 63%, and 30%, respectively). When these criteria were combined, the sensitivity increased to 72%. A PSV >200 cm/s combined with either an EDV >140 cm/s or a carotid index >4.5 has a sensitivity of 96% and a specificity of 61%. Conclusions Doppler criteria can be both specific and sensitive for detecting a significant stenosis, defined as a ≤1.5 mm residual lumen diameter. By adjustment of the velocity criteria, it can be 100% specific or a highly sensitive test (96%).

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 62 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3