Diagnostic Accuracy of Magnetic Resonance Angiography for Cerebral Aneurysms in Correlation With 3D–Digital Subtraction Angiographic Images

Author:

Okahara Mika1,Kiyosue Hiro1,Yamashita Masanori1,Nagatomi Hirohumi1,Hata Hiroyuki1,Saginoya Toshiyuki1,Sagara Yoshiko1,Mori Hiromu1

Affiliation:

1. From the Departments of Neuroradiology (M.O., H.K.) and Neurosurgery (M.Y., H.N.), Nagatomi Neurosurgical Hospital, and the Department of Radiology (H.H., T.S., Y.S., H.M.), Oita Medical University, Oita, Japan.

Abstract

Background and Purpose We investigated the sensitivity of 3D–time-of flight (3D-TOF) magnetic resonance angiography (MRA) in the detection of cerebral aneurysms with the use of 3D digital subtraction angiography as the gold standard. We also evaluated the effects of location and number of aneurysms (and experience of the reader) on the sensitivity. Methods 3D-TOF MRA was performed in 82 patients with 133 cerebral aneurysms. Each patient underwent rotational angiography. Three-dimensional reconstructed images were obtained from data of the rotational angiography (as the gold standard). A blind study with 4 readers of different experiences was performed to evaluate the diagnostic accuracy of 3D-TOF MRA for cerebral aneurysms. Results One hundred five (79%) of all 133 aneurysms were detected with MRA by a neuroradiologist, 100 (75%) were detected by an experienced neurosurgeon, 84 (63%) were detected by a general radiologist, and 80 (60%) were detected by a resident neuroradiologist. For each reader, the detectability was lower for small aneurysms (<3 mm in maximum diameter) and/or for those located at the internal carotid artery and anterior cerebral artery. False-positive aneurysms were 29 for the neuroradiologist, 19 for the neurosurgeon, 31 for the general radiologist, and 30 for the resident neuroradiologist; most of the aneurysms were at the internal carotid artery. Causes of the false-positive and false-negative results included complex flow in a tortuous artery and susceptibility artifacts. Conclusions Although MRA is useful in the diagnosis of cerebral aneurysms, sufficient experience and careful attention are necessary for accurate diagnosis of aneurysms located at the internal carotid and anterior cerebral arteries.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3