Common Carotid Intima-Media Thickness and Risk of Acute Myocardial Infarction

Author:

Bots Michiel L.1,Grobbee Diederick E.1,Hofman Albert1,Witteman Jacqueline C.M.1

Affiliation:

1. From the Julius Center for Health Sciences and Primary Care (M.L.B., D.E.G.), Univeristy Medical Center Utrecht, Utrecht; and the Department of Epidemiology and Biostatistics (A.H., J.C.M.W), Erasmus Medcal Cente, Rotterdam, The Netherlands.

Abstract

Background— It has been argued that lumen diameter of the common carotid artery should be taken into account in analyses on common carotid intima-media thickness (CIMT) and cardiovascular risk. Yet, no published report has dealt with this issue in detail. Methods— In the Rotterdam study baseline ultrasound images of the carotid arteries were made. During follow-up of 8.2 years, 656 new acute myocardial infarctions (AMI) occurred. Regression analysis was used to study myocardial infarction relation to right (or left) common CIMT with various adjustments for right-, or left-sided lumen diameter. Lumen adjustment was made by (1) a simple adjustment in a regression equation; (2) using the CIMT-to-lumen ratio; (3) using arterial mass, calculated as ({π×[(lumen+near wall CIMT+far wall CIMT)/2] 2 }−[π×(lumen/2) 2 ]). Results— AMI disease risk increased per standard deviation increase in common CIMT (0.177 mm): hazard ratio (HR) 1.28 (95% CI, 1.19 to 1.37). When lumen diameter was taken into account the HR was 1.26 (95% CI, 1.18 to 1.35). The HR for the CIMT-to-lumen ratio was 1.18 (95% CI, 1.11 to 1.27) and for arterial mass 1.28 (95% CI, 1.19 to 1.37). Additional analyses indicated that the CIMT-to-lumen ratio at lower CIMT levels appears to reflect arterial remodelling rather than risk of cardiovascular disease. Conclusion— We conclude that using the CIMT-to-lumen ratio yields the weakest associations. Other approaches for adjustment for common carotid lumen diameter do not affect the magnitude or precision of the association of common CIMT to risk of AMI. When the interest is in risk relations the preference goes to either CIMT or arterial mass measurement.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3