Optimizing the Technique of Contrast Transcranial Doppler Ultrasound in the Detection of Right-to-Left Shunts

Author:

Droste Dirk W.1,Lakemeier Stefan1,Wichter Thomas1,Stypmann Jörg1,Dittrich Ralf1,Ritter Martin1,Moeller Martin1,Freund Michael1,Ringelstein E. Bernd1

Affiliation:

1. From the Departments of Neurology (D.W.D., S.L., R.D., M.R., E.B.R.), Cardiology and Angiology (T.W., J.S.), and Clinical Radiology (M.M., M.F.), University of Münster, Münster, Germany.

Abstract

Background and Purpose— A cardiac right-to-left shunt (RLS) can be identified by transesophageal echocardiography and transcranial Doppler ultrasound (TCD) with contrast agents and a Valsalva maneuver (VM) as a provocation procedure. This article applies the modalities of these tests detailed in previous studies to a large patient cohort and compares 2 contrast agents (saline and Echovist-300). Methods— Eighty-one patients were investigated by both transesophageal echocardiography and bilateral TCD of the middle cerebral arteries. The following protocol with injections of 10 mL agitated saline was applied in a randomized way: (1) no VM, (2) VM for 5 seconds starting 5 seconds after the beginning of contrast injection, and (3) repetition of the test with VM if the first test with VM was negative. The VM was performed for 5 seconds starting exactly 5 seconds after the beginning of saline injection. Thereafter, the same protocol was repeated with 10 mL Echovist-300 instead of saline. Results— Thirty-one patients had a cardiac RLS. The Echovist-300 investigation disclosed all these 31 shunts, but saline disclosed only 29 of them. Twenty-two had an RLS only in at least 1 of the above TCD tests, some of them even with a considerable shunt volume. Conclusions— Contrast TCD performed with Echovist-300 but not with saline yields a 100% sensitivity to identify transesophageal echocardiography-proven cardiac RLSs. The TCD test should be repeated if negative the first time. This article gives detailed information for the optimization of the contrast TCD technique. Extracardiac shunts detected only during contrast TCD can have a considerable shunt volume and may allow for paradoxical embolism.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 88 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3