Visualization of subendocardial myocardial ischemia with myocardial contrast echocardiography in humans.

Author:

Lim Y J1,Nanto S1,Masuyama T1,Kodama K1,Ikeda T1,Kitabatake A1,Kamada T1

Affiliation:

1. Cardiovascular Division, Kawachi General Hospital, Osaka, Japan.

Abstract

Previous studies indicate the degree of myocardial echo contrast enhancement may be related to regional myocardial perfusion. In this study, myocardial contrast echocardiography was used to characterize changes in the transmural myocardial blood flow distribution that were provoked by rapid atrial pacing in 11 patients with one-vessel coronary artery disease. Ten patients without coronary artery disease served as controls. Myocardial contrast echocardiography was performed by intracoronary injection of 2 ml hand-agitated amidotrizoate sodium meglumine (Urografin-76) and by imaging a short-axis view of the left ventricle with two-dimensional echocardiography before and during injection of the contrast agent. The two-dimensional echocardiographic images at end diastole, before and after injection of the contrast agent, were digitized off-line into a 512 x 512 pixel matrix with 256 gray levels/pixel to quantify the degree of the enhancement of the peak gray level after injection. Transmural myocardial blood flow distribution was evaluated by measuring the ratio of the enhanced gray level in the endocardial half (endo) to that in the epicardial half (epi) (endo:epi gray level ratio) in the anteroseptal, posterolateral, and inferior segments before and just after rapid atrial pacing in each patient. In patients without coronary artery disease, there were no differences in the endo:epi gray level ratio between any of the three segments both before and after pacing. Mean values of the three segments were 0.95 +/- 0.08 before pacing and 0.90 +/- 0.13 after pacing, respectively. In contrast, in patients with coronary artery disease, the endo:epi gray level ratio for the segment supplied with stenotic coronary artery decreased after pacing (0.40 +/- 0.21 vs. 0.93 +/- 0.18, p less than 0.01), probably reflecting subendocardial myocardial ischemia, whereas that for the segment supplied with nonstenotic coronary artery remained unchanged (0.88 +/- 0.20 vs. 0.99 +/- 0.23, NS). Thus, changes in transmural myocardial blood flow distribution with rapid pacing, which may be due to transient subendocardial ischemia, are visualized with myocardial contrast echocardiography.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 68 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3