Right ventricular and right atrial collapse in patients with cardiac tamponade--a combined echocardiographic and hemodynamic study.

Author:

Singh S,Wann L S,Schuchard G H,Klopfenstein H S,Leimgruber P P,Keelan M H,Brooks H L

Abstract

To determine the hemodynamic derangement associated with right ventricular diastolic collapse and to assess the value of right ventricular and right atrial collapse in identifying cardiac tamponade, two-dimensional echocardiograms were recorded simultaneously with measurement of right atrial, pulmonary capillary wedge, intrapericardial, and systemic arterial pressures and cardiac output in 16 patients as they underwent pericardiocentesis. Twelve patients (group I) had evidence of right ventricular or right atrial collapse or both on their echocardiograms and hemodynamic evidence of cardiac tamponade before pericardiocentesis. All hemodynamic parameters improved after pericardiocentesis (p less than or equal to .05). Continuous monitoring during pericardiocentesis in three of these patients showed significant improvement in all parameters except heart rate (p less than or equal to .02) at the point of disappearance of right ventricular diastolic collapse, with further improvement in cardiac output as pericardiocentesis continued (p less than .01). Right atrial collapse persisted after right ventricular collapse disappeared but was no longer present when pericardiocentesis was completed. Three patients (group II) had no right ventricular or right atrial collapse, no hemodynamic evidence of cardiac tamponade, and no improvement in hemodynamic parameters after pericardiocentesis. A single patient (group III) was found to have elevated right heart pressures and right ventricular hypertrophy before pericardiocentesis. Although there was hemodynamic evidence of cardiac tamponade in this patient, there was no evidence of right ventricular or right atrial collapse. In this study, the sensitivity of right ventricular collapse as a marker for cardiac tamponade was 92%, its specificity 100%, its accuracy 94%, and its predictive value 100%.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 249 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3