Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans.

Author:

Quigley P J1,Hinohara T1,Phillips H R1,Peter R H1,Behar V S1,Kong Y1,Simonton C A1,Perez J A1,Stack R S1

Affiliation:

1. Department of Medicine, Duke University Medical Center, Durham, North Carolina 27710.

Abstract

An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between two inflations by standard angioplasty catheters. Chest pain score, 12-lead electrocardiogram, heart rate, and mean aortic pressure were recorded before each inflation and at 1-minute intervals after inflation. Inflation duration during autoperfusion angioplasty (513 +/- 303 seconds) was longer than for the pre- (107 +/- 55 seconds, p = 0.0004) and post- (139 +/- 71 seconds, p = 0.0006) standard dilatations. The maximum ST-segment elevation and depression in any lead during autoperfusion angioplasty (0.3 +/- 0.5 and 0.6 +/- 0.8 mm) was significantly less than for the pre- (2.4 +/- 1.7 mm, p = 0.002 and 2.2 +/- 1.3 mm, p = 0.0004) or post- (1.9 +/- 1.3 mm, p = 0.002 and 1.6 +/- 1.3 mm, p = 0.018) standard dilatations at the same point in time. Maximal chest pain score during autoperfusion (3.2 +/- 3.5) was lower than for the pre- (6.1 +/- 2.1, p = 0.003) but not the post- (5.2 +/- 3.1, p = 0.07) standard angioplasty. All 11 patients underwent successful, uncomplicated procedures. We conclude that this autoperfusion catheter significantly reduces ischemic symptoms and signs during coronary angioplasty, allowing prolonged periods of balloon inflation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference26 articles.

1. Prolonged application of pressure in transluminal coronary angioplasty

2. Acute coronary artery occlusion during percutaneous transluminal coronary angioplasty treated by redilation of the occluded segment

3. Can prolonged application of pressure improve the results of coronary angioplasty (PTCA) (abstract);Kaltenbach M;Circulation,1982

4. The perfusion balloon catheter: A new method for safe prolonged coronary dilatation (abstract);Collins GJ;J Am Coll Cardiol,1987

Cited by 100 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3