Color Doppler flow mapping in patients with coarctation of the aorta: new observations and improved evaluation with color flow diameter and proximal acceleration as predictors of severity.

Author:

Simpson I A1,Sahn D J1,Valdes-Cruz L M1,Chung K J1,Sherman F S1,Swensson R E1

Affiliation:

1. Division of Pediatric Cardiology, University of California, San Diego, La Jolla.

Abstract

We performed color Doppler flow mapping in 15 patients, 1 week to 17 years old (mean 42 months), with coarctation of the aorta that was confirmed subsequently by angiography and/or surgery. Twelve patients had native coarctation and three had mild recoarctation after surgical repair. Color Doppler flow maps were analyzed with a digital analysis package and a Sony computer system. The diameter in the region of coarctation from the color Doppler flow map (mean = 2.0 +/- 0.8 mm [SD]) correlated well with the coarctation diameter measured at angiography (mean = 1.8 +/- 0.8 mm; r = .83, SEE 0.43 mm) in the 10 patients with native coarctation undergoing angiography, but the coarctation diameter measured by two-dimensional echocardiography (3.9 +/- 1.5 mm) was poorly predictive of the angiographic severity (r = .23). Additionally, spatial acceleration was seen in all patients proximal to the coarctation site, with an aliased and accelerating stream narrowing progressively as it proceeded toward the coarctation site, a pattern that is not seen in healthy subjects. Computer analysis of the color Doppler images provided pseudo three-dimensional and digital velocity maps for blue, red, and green (turbulent) flow velocities to allow an enhanced appreciation of the accelerating stream, easily separating this from normal descending aortic aliasing patterns. The narrowing of the acceleration area in the proximal descending aorta (distal/proximal acceleration zone ratio) was also predictive of the angiographic severity of coarctation (r = .83). The distribution of low-level turbulence seen proximally paralleled the distribution of the proximal accelerating stream.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 79 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Coarctation of the Aorta;Pediatric Cardiac Surgery;2023-02-03

2. The Coarctation of Aorta;Clinical and Surgical Aspects of Congenital Heart Diseases;2023

3. Coarctation of the aorta and interrupted aortic arch;Perloff's Clinical Recognition of Congenital Heart Disease;2023

4. Point-of-care ultrasound for children;Journal of Medical Ultrasonics;2022-01-21

5. Role of Echocardiography in Percutaneous Closure of Patent Ductus Arteriosus;Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging;2022