Influence of two-stage anatomic correction on size and distensibility of the anatomic pulmonary/functional aortic root in patients with simple transposition of the great arteries.

Author:

Sievers H H,Lange P E,Arensman F W,Radley-Smith R,Yacoub M H,Harms D,Heintzen P H,Bernhard A

Abstract

To evaluate the results of the two-stage anatomic correction of simple transposition of the great arteries the size, distensibility, and histologic characteristics of the anatomic pulmonary root, which arises from the anatomic left ventricle and which we termed the functional aortic root after anatomic correction, were determined in seven patients before and twice after anatomic correction (mean 43 and 671 days) and the results were compared with those in normal control subjects. The diameter of the systolic sinus of the anatomic pulmonary root increased after banding on the average to 140% of normal, whereas the diameter of the diastolic sinus of the functional aortic root increased after anatomic correction on the average to 150% of normal. Diameters of both the systolic and diastolic sinuses of the functional aortic root remained 30% to 55% larger than normal after anatomic correction. Growth potential of the functional aortic root after anatomic correction was normal, whereas its distensibility, as assessed by determination of the percent change in radius and pressure-strain elastic modulus (stiffness index), was decreased after anatomic correction. This pressure-strain elastic modulus was directly related to the corresponding body surface area and age at banding. In four of five specimens of the anatomic pulmonary arterial wall that were obtained at the time of anatomic correction, fragmentation and shortening of elastic fibers were observed. The histologic characteristics of the pulmonary root in the patient with the smallest body surface area at banding and normal distensibility of the anatomic pulmonary/functional aortic root before and after anatomic correction revealed normal aortic configuration of the elastic tissue.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3