Power spectrum analysis of heart rate variability in human cardiac transplant recipients.

Author:

Sands K E1,Appel M L1,Lilly L S1,Schoen F J1,Mudge G H1,Cohen R J1

Affiliation:

1. Harvard-Massachusetts Institute of Technology, Division of Health Sciences and Technology, Cambridge 02139.

Abstract

Beat-to-beat heart rate variability was studied by power spectral analysis in 17 orthotopic cardiac transplant patients. Heart rate power spectra were calculated from eighty-four 256-second recordings and compared with those taken from six normal subjects. The power spectra from the control subjects resolved into discrete peaks at 0.04-0.12 Hz and 0.2-0.3 Hz, whereas those of heart transplant recipients resembled broad-band noise without peaks. Log total power in the 0.02-1.0 Hz range was greater in the control subjects (0.982 +/- 0.084 [0.206], mean +/- SEM [SD]) than in the transplanted subjects (-0.766 +/- 0.059 [0.541]), (p less than 0.0001). Fifty-five electrocardiographic recordings from transplant patients were done within 48 hours of an endomyocardial biopsy. When the power spectra of those patients whose endomyocardial biopsies showed evidence of myocardial rejection were compared with those from patients who were found to be free of rejection, a significant difference was found in log total power (-0.602 +/- 0.090 [0.525] vs. -0.909 +/- 0.136 [0.577], p less than 0.02). We conclude that denervation of the heart significantly reduces heart rate variability and abolishes the discrete spectral peaks seen in untransplanted control subjects and that the development of allograft rejection may significantly increase heart rate variability.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference20 articles.

1. Hemodynamic regulation by spectral analysis;Akselrod S;Am J Physiol,1985

2. Analysis of Heart Rate Variability

3. Influence of cardiac neural inputs on rhythmic variations of heart period in the cat;Chess GF;Am J Physiol,1975

4. Power Spectrum Analysis of Heart Rate Fluctuation: A Quantitative Probe of Beat-to-Beat Cardiovascular Control

5. Tu JC: A microprocessor based system for spectral analysis of low frequency physiologic signals. Masters Thesis Department of Electrical Engineering MIT 1983