Right atrial pressure-volume relationships in tricuspid regurgitation.

Author:

Miller M J,McKay R G,Ferguson J J,Sahagian P,Nakao S,Come P C,Grossman W

Abstract

Pressure-volume relationships in the right atrium were examined before and after the creation of acute experimental tricuspid regurgitation in pigs. A 1.3 kHz multielectrode impedance catheter with a measuring current of 4 mA was used to determine instantaneous right atrial pressure and relative blood volume; right atrial dimension was assessed simultaneously with ultrasonic crystals attached to the atrial walls. Impedance volume waveforms and ultrasonic crystal dimensions closely paralleled each other at baseline and after the induction of tricuspid regurgitation. The normal right atrial pressure-volume plot exhibited a figure-of-eight configuration, with an "a-loop" and a "v-loop" corresponding to the a-wave and v-wave of the right atrial pressure tracing. With severe tricuspid regurgitation, atrial pump function was abolished, and the pressure-volume plot exhibited a single clockwise loop, consistent with complete ventricularization of the right atrium. Intermediate degrees of tricuspid regurgitation preserved the figure-of-eight loop, but the size of both the a-loop and the v-loop were increased, consistent with a Starling-type load imposed on the atrium by the regurgitant blood volume. Increased right ventricular afterload mediated by constriction of the pulmonary artery and infusion of methoxamine reversibly converted the right atrial pressure-volume loop from that of mild to that of severe tricuspid regurgitation. Alternatively, constriction of the inferior vena cava and infusion of nitroprusside changed the right atrial pressure-volume loop from that of a severe pattern of tricuspid regurgitation to a less severe type of pattern. Infusion of dobutamine increased the size of the a-loop relative to the v-loop both at baseline and after induction of tricuspid regurgitation. We conclude that tricuspid regurgitation induces changes in right atrial mechanics that can be detected and quantified with an impedance catheter.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference25 articles.

1. Diagnosis of tricuspid regurgitation. Current status

2. Diagnostic tests for tricuspid insufficiency: How good?

3. DePace NL Ross J Iskandrian AS Nestico PF Kotier MN Mintz GS Segal BL Hakki AH Morganroth J: Tricuspid regurgitation:

4. Is tricuspid valve repair necessary?;Duran CMU;J Thorac Cardiovasc Surg,1980

5. Echocardiographic evaluation of tricuspid valve endocarditis

Cited by 37 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Method for measuring jugular venous pulse with a miniature gyroscope sensor patch;2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC);2023-07-24

2. Clinical relevance and prognostic value of renal Doppler in acute decompensated precapillary pulmonary hypertension;European Heart Journal - Cardiovascular Imaging;2023-05-17

3. Clinical utility and prognostic value of right atrial function in severe tricuspid regurgitation: one more piece of the puzzle;European Heart Journal - Cardiovascular Imaging;2023-04-19

4. Tricuspid surgery at the time of LVAD implant: A critique;Frontiers in Cardiovascular Medicine;2022-11-21

5. Strategies for diagnosis of fetal right atrium dilation: based on fetal cardiac anatomy and hemodynamics;BMC Medical Imaging;2020-07-06