Regional wave travel and reflections along the human aorta: a study with six simultaneous micromanometric pressures.

Author:

Latham R D,Westerhof N,Sipkema P,Rubal B J,Reuderink P,Murgo J P

Abstract

The human aorta and its terminal branches were investigated in normal subjects during elective cardiac catheterization to evaluate regional wave travel and arterial wave reflections. A specially designed catheter with six micromanometers equally spaced at 10 cm intervals was positioned with the tip sensor in the distal external iliac artery and the proximal sensor in the aortic arch. Simultaneous pressures were obtained and analyzed for foot-to-foot wave velocity, and Fourier analysis was used to derive apparent phase velocity. These quantities were assessed during control (n = 9), during Valsalva (n = 8) and Müller (n = 4) maneuvers, and during femoral artery occlusion by bilateral manual compression (n = 8). During control, regional cross-sectional areas, determined from aortography, and regional foot-to-foot pulse wave velocities were used to calculate the local reflection coefficient in the proximal descending aorta (gamma = 0.05), at the junction of the renal arteries (gamma = 0.43), and at the terminal aortic bifurcation (gamma = 0.13). To test the hypothesis that significant reflections originate in the aorta, at the level of the renal arteries, aortograms were used to design a latex tube model with geometric properties similar to the descending aorta. Velocities and reflection characteristics in the model and in vivo were compared. Inspection of thoracic aortic pressures under control conditions revealed a reflected wave originating from the region of the aorta at the level of the renal arterial branches while abdominal pressures exhibited reflection from a site peripheral to the terminal aortic bifurcation. In the low frequency range, apparent phase velocity was found to be higher proximal to the renal arteries as compared with at the distal sites. In addition, the minimum value occurred at a higher frequency in the lower thoracic aorta than at more distal sites. The effects of reflection on apparent wave velocity in the tube model were consistent with data obtained in vivo. The Valsalva maneuver diminished the reflection from the aortic region of the renal arteries, thus allowing the distal reflected wave to become more evident on the thoracic pressure waveforms. Bilateral femoral artery occlusion usually enhanced the distal reflection and the Müller maneuver usually resulted in small increases in reflections. In conclusion, the geometric and elastic nonuniformity of the aorta results in two major sites of arterial wave reflection that influence the aortic pressure waveforms in man.(ABSTRACT TRUNCATED AT 400 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference50 articles.

1. O'Rourke MF: Arterial function in health and disease. Edinburgh 1982 Churchill Livingstone

2. Instantaneous Pressure Distribution Along the Human Aorta

3. McDonald DA: Blood flow in arteries ed 2. Baltimore 1974 Williams and Wilkins Company pp 254 309 351 392

4. The patterns of the arterial pressure pulse;Hamilton WF;Am J Physiol,1944

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3