Comparison of bipolar and unipolar programmed electrical stimulation for the initiation of ventricular arrhythmias: significance of anodal excitation during bipolar stimulation.

Author:

Stevenson W G,Wiener I,Weiss J N

Abstract

To determine if anodal excitation during bipolar stimulation facilitates the initiation of sustained monomorphic ventricular tachycardia, nonsustained polymorphic ventricular tachycardia, or repetitive ventricular responses, both bipolar and cathodal unipolar programmed ventricular stimulation with one to three extrastimuli delivered during ventricular pacing at two rates from the right ventricular apex were performed in 28 patients evaluated for spontaneous sustained ventricular tachycardia or ventricular fibrillation (11 patients), nonsustained tachycardia (eight patients), or syncope (nine patients). In 25 patients a hexapolar pacing catheter was used to record local endocardial activation times adjacent to the cathode and anode and ventricular excitation during bipolar stimulation was defined as predominantly anodal, cathodal, or simultaneous at both anode and cathode. When bipolar and unipolar stimulation were compared there was no difference in the incidence of initiating sustained monomorphic ventricular tachycardia (57% vs 57%), nonsustained polymorphic ventricular tachycardia (14% vs 14%), or repetitive ventricular responses (21% vs 21%), although the response to bipolar vs unipolar stimulation was not concordant in every patient. Evidence of anodal excitation was observed in 11 (44%) patients but did not indicate increased risk of initiation of any ventricular arrhythmia, despite the fact that it was associated with shortening of the ventricular effective refractory period by 5.2 +/- 8.7 msec (p less than .05) during bipolar as opposed to unipolar stimulation. We conclude that unipolar and bipolar stimulation produce a similar incidence of initiation of arrhythmia, despite the frequent occurrence of anodal excitation during bipolar stimulation. Thus, the risk of initiation of nonspecific ventricular arrhythmias during programmed stimulation is unlikely to be reduced by the use of unipolar stimulation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3