A Doppler-two-dimensional echocardiographic method for quantitation of mitral regurgitation.
-
Published:1985-08
Issue:2
Volume:72
Page:377-383
-
ISSN:0009-7322
-
Container-title:Circulation
-
language:en
-
Short-container-title:Circulation
Author:
Ascah K J,Stewart W J,Jiang L,Guerrero J L,Newell J B,Gillam L D,Weyman A E
Abstract
A noninvasive method to accurately quantitate the severity of mitral insufficiency would be of major clinical value. In theory, in the absence of confounding variables, regurgitant mitral flow should represent the difference between forward mitral blood flow and aortic blood flow. Since Doppler-two-dimensional echocardiographic (D2DE) methods for measuring transvalvular mitral and aortic flow have been validated, it should be possible to use mitral and aortic flows derived by this method to calculate regurgitant mitral flow. To assess the validity and accuracy of this combined approach for quantitation of regurgitant flow, we developed an open-chest canine preparation in which we could simulate, vary, and accurately measure degrees of mitral regurgitation. Seven animals were anesthetized and prepared to allow controlled right heart output. Mitral regurgitation was than simulated by placing a flexible conduit incorporating a one-way valve and electromagnetic flowmeter between the left ventricular apex and left atrium. Flow through the tube (effective mitral regurgitation) was varied between 0.2 and 1.8 liters/min and forward cardiac output ranged between 0.5 and 4 liters/min. Transmitral and transaortic flows were calculated by previously reported Doppler methods. Doppler-derived estimates of forward flow through the aortic valve correlated well with the flow measured by flowmeter (r = .92), and regurgitant flow and regurgitant fraction calculated by the D2DE approach also compared well with those measured by flowmeter (r = .84 and .83, respectively). This study demonstrates that mitral regurgitant flow and regurgitant fraction calculated by the D2DE method provide an acceptable measure of both absolute regurgitant flow and the regurgitant fraction in the experimental setting.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Reference21 articles.
1. Braunwald E: Heart disease: a textbook of cardiovascular medicine. Philadelphia 1980 W.B. Saunders and Company p 11 17
2. Left retrograde cardioangiography in acquired cardiac disease
3. Quantitation of valvular insufficiency in man by angiocardiography
4. Weyman AE: The left ventricular inflow tract part 1: the mitral valve. In Weyman AE editor: Cross-sectional echocardiography. Philadelphia 1982 Lea and Febiger pp 139-192
Cited by
75 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Mitral Regurgitation;Practice of Clinical Echocardiography;2017
2. Echocardiography of the Mitral Valve;Progress in Cardiovascular Diseases;2014-07
3. Complementary Use of Imaging modalities in Diagnosis of Complex Congenital Heart Disease;ASEAN Heart Journal;2014-04
4. Mitral Insufficiency;Principles of Echocardiography;2012
5. Cardiac Imaging in the Elderly;Cardiothoracic Surgery in the Elderly;2011