Electrical alternans and cardiac electrical instability.

Author:

Smith J M1,Clancy E A1,Valeri C R1,Ruskin J N1,Cohen R J1

Affiliation:

1. Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139.

Abstract

We investigated the relationship between electrical alternans and cardiac electrical stability in a series of 20 dog experiments and in a pilot clinical study. Electrical alternans was detected in both the QRS complex and the ST-T wave by use of a novel multidimensional spectral technique. The magnitude of the alteration was expressed as the alternating electrocardiographic morphology index (AEMI), expressed as parts per million of waveform energy. Electrical stability in the dog preparations was assessed via the ventricular fibrillation threshold measurement, and in the clinical studies via programmed stimulation. In 10 dog experiments, systemic hypothermia resulted in a 60% decrease in ventricular fibrillation threshold (VFT) (p less than .0001) and a significant increase in both AEMI(QRS) form 3.7 +/- 3.0 to 1448 +/- 548 (p less than .0001) and AEMI(ST-T) from 43.9 +/- 18.4 to 19,178 +/- 5579 (p less than .0001). In 10 dog experiments, transient coronary artery ligation also resulted in a 60% decrease in VFT (p less than .0001), an increase from 76.3 +/- 46.5 to 245 +/- 11 in AEMI(QRS) (p less than .05), and an increase from 842 +/- 505 to 1365 +/- 392 in AEMI(ST-T) (p less than .002). In 119 observations in 20 animal experiments, the rank correlation between VFT and AEMI(QRS) was -.30 (p less than .001), with that between VFT and AEMI(ST-T) being -.55 (p less than .0001). In a double-blind pilot clinical trial consisting of 23 studies in 19 patients, the result of electrophysiologic testing was used as an independent measure of cardiac electrical stability. Alternation in waveform morphology identified the inducible patient population with a sensitivity of 92%, a positive predictivity of 70%, and a specificity of 50% (p less than .05). We conclude that analysis of subtle beat-to-beat variability in electrocardiographic morphology may provide a noninvasive measure of cardiac electrical stability.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 418 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3