Influence of alteration in preload on the pattern of left ventricular diastolic filling as assessed by Doppler echocardiography in humans.

Author:

Stoddard M F1,Pearson A C1,Kern M J1,Ratcliff J1,Mrosek D G1,Labovitz A J1

Affiliation:

1. Department of Internal Medicine, St. Louis University School of Medicine, Missouri.

Abstract

We examined the influence of alterations in preload on pulsed Doppler indexes of left ventricular diastolic function in 50 patients including 12 without cardiovascular disease, 29 with coronary artery disease, and nine with critical aortic stenosis. Micromanometer left ventricular pressure was recorded simultaneously with pulsed Doppler echocardiography of left ventricular inflow and M-mode echocardiography of left ventricular diameter. Chamber stiffness constants, kd and kv, were obtained from the diastolic pressure-diameter and pressure-volume relations, respectively. Relaxation was measured by the isovolumic relaxation time constants, TL and TD, derived from the exponential left ventricular pressure decay and maximum negative dP/dt. In 41 patients after nitroglycerin treatment, left ventricular end-diastolic pressure decreased from 18 +/- 5 to 13 +/- 4 mm Hg (p less than 0.001). The ratio of peak early to peak atrial filling velocities and time-velocity integral ratios decreased from 1.08 +/- 0.57 to 0.90 +/- 0.42 (p less than 0.001) and from 1.77 +/- 0.95 to 1.41 +/- 0.71 (p less than 0.001), respectively. The peak early filling velocity and time-velocity integral decreased from 56.1 +/- 15.7 to 49.9 +/- 14.5 cm/sec (p less than 0.001) and from 7.9 +/- 2.7 to 6.8 +/- 2.8 cm (p less than 0.001), respectively. Relaxation (TL, TD, and maximum negative dP/dt) and chamber stiffness (kd and kv) were not impaired after nitroglycerin administration. In 48 patients after ventriculography, left ventricular end-diastolic pressure increased from 18 +/- 6 to 22 +/- 8 mm Hg (p less than 0.001). The peak early and peak atrial filling velocities increased from 57.4 +/- 15.2 to 68.3 +/- 19.7 cm/sec (p less than 0.001) and from 61.0 +/- 22.7 to 69.4 +/- 23.2 cm/sec (p less than 0.01), respectively. As a result, the ratio of peak early to peak atrial filling velocity was unchanged. However, in the aortic stenosis group, the ratio of peak early to peak atrial filling velocity increased from 0.95 +/- 0.64 to 1.10 +/- 0.72 (p less than 0.02). Relaxation and chamber stiffness were unchanged. Thus, a reduction or increase in preload may induce a diastolic filling pattern that mimics or masks diastolic dysfunction, respectively. Preload conditions need to be accounted for when the status of diastolic function is extrapolated from the pulsed Doppler mitral inflow velocity profile.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3