Regional myocardial and organ blood flow after myocardial infarction: application of the microsphere principle in man.

Author:

Selwyn A P,Shea M J,Foale R,Deanfield J E,Wilson R,de Landsheere C M,Turton D L,Brady F,Pike V W,Brookes D I

Abstract

A physiologic means of measuring the distribution of cardiac output and regional myocardial blood flow has been developed that uses human albumin microspheres labeled with carbon-11 (11C) and external detection with positron emission tomography. Ten patients with previous myocardial infarction were studied to investigate the level of blood flow in normal and infarcted segments of the heart. After diagnostic catheterization, 4 to 6 mCi of 11C on 2 to 3 million sterile microspheres (15 to 20 micron) were mixed and injected into the apex of the left ventricle during timed withdrawal of arterial blood to obtain reference flow values. Regional activity in brain, heart, lungs, liver, spleen, and kidneys was measured tomographically. Blood flow was calculated based on the relationship between total activity in a reference flow and tissue activity in tomograms of each organ (ml/min/100 g). No adverse effects were noted after injection of the microspheres. Successive myocardial tomograms showed no loss of activity. There were no significant differences in flow values in matched regions of paired organs. Mean cerebral flow was 52.4 +/- 10.0 ml/min/100 g in the frontal lobes, 54.4 +/- 8.8 in the temporal lobes, 67.6 +/- 8.2 in the occipital lobes, and 53.0 +/- 9.4 in the basal ganglia. Flow was 16.0 +/- 8.4 ml/min/100 g (range 0 to 40.0) in the center of infarcted myocardium and 82.0 +/- 32.0 in the remote segments. This method meets most of the demands for use of microspheres to measure tissue blood flow. The wide range of flow values in infarcted myocardium may be a function of infarct size, spatial resolution, or pathologic evidence of islands of viable tissue. Patients with angina had high flow values in the infarcted segment, whereas those with heart failure had significantly lower values. Surviving myocardium in the region of the infarct may need to be considered if patients complain of angina, particularly when treatment is aimed at preserving ventricular function.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference51 articles.

1. Wootton R: Theory of blood flow measurements with tracers. In Mathie RT editor: Blood flow measurement in man. London 1982 Oxford University Press p 3

2. Blood flow measurements with radionuclide-labeled particles

3. Preparation of human serum [methyl-11C]methylalbumin microspheres and human serum [methyl-11C]methylalbumin for clinical use

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3