Diminished stroke volume during inspiration: a reverse thoracic pump.

Author:

Olsen C O,Tyson G S,Maier G W,Davis J W,Rankin J S

Abstract

In 12 conscious dogs, a three-dimensional array of pulse-transit ultrasonic transducers was used to measure left ventricular anterior-posterior minor, septal-free wall minor, and basal-apical major diameters. Matched micromanometers measured left ventricular, right ventricular, and intrapleural pressures. Electromagnetic ascending aortic blood flow and right ventricular transverse diameter were measured in five of the dogs. A major cause of the inspiratory decline in stroke volume in this preparation appeared to be reflex tachycardia and autonomic changes associated with inspiration. However, when heart rate was controlled by atrial pacing or pharmacologic autonomic attenuation (propranolol and atropine), stroke volume still decreased around 10%, with an inspiratory decrease in pleural pressure of 10 mm Hg. Based on the measurements of ventricular dimension, venous return to the right ventricle appeared to be augmented significantly during inspiration and the transient increase in right ventricular volume was associated with leftward interventricular septal shifting and altered diastolic left ventricular geometry. However, left ventricular end-diastolic volume was changed minimally, implying that alterations in preload were not important. Moreover, transmural left ventricular ejection pressure, calculated as intracavitary minus pleural pressure, was not significantly changed, and it seemed that neither pressure nor geometric components of afterload were altered significantly by inspiration. The inspiratory fall in left ventricular stroke volume correlated best with the decline in intracavitary left ventricular ejection pressure referenced to atmospheric pressure. It is hypothesized that during ejection, left ventricular pressure referenced to atmospheric pressure is the hydraulic force effecting stroke volume and that the decline in this effective left ventricular ejection pressure is responsible for the inspiratory fall in stroke volume through a reverse thoracic pump mechanism.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference40 articles.

1. Breecher GA: The respiratory pump. In Venous return. New York 1956 Grune and Stratton pp 71-90

2. Charlier AA: Beat to beat hemodynamic effects of Iung inflation and normal respiration in anaesthetized and conscious dogs. Brussels 1967 Editions Arscia pp 75-94

3. Franklin KJ: Respiration and the venous return in mammals; the "'vis a fronte." In A monograph on veins. Springfield IL 1937 Charles C Thomas ch 19 pp 236-267

4. Hales S: I. An account of some hydraulick and hydrostatical experiments made on the blood and blood-vessels of animals. In Statistical essays: containing haemastaticles. London 1773 Innys Manby and Woodward pp 1-3

5. Cardiac Response to Increased Aortic Pressure Changes in Output and Left Ventricular Pressure Pattern at Various Levels of Inotropy

Cited by 65 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3