The implantable transvenous cardioverter: long-term efficacy and reproducible induction of ventricular tachycardia.

Author:

Miles W M,Prystowsky E N,Heger J J,Zipes D P

Abstract

We followed 11 patients for 5 to 27 months (mean 14.9) after implantation of a permanent transvenous low-energy synchronized cardioverter to evaluate both long-term reproducibility of ventricular tachycardia (VT) induction via noninvasive programmed electrical stimulation with the cardioverter and efficacy of cardioversion. Induction and termination of VT were attempted at implantation and approximately every 3 months thereafter. All patients had coronary artery disease and were receiving antiarrhythmic drug therapy (amiodarone in eight). VT cycle length, morphology, and mode of induction were reproducible on multiple occasions in nine patients; clinical VT was induced inconsistently in two patients. Multiple VT episodes in five patients had one morphology, whereas two morphologies occurred in six patients. Synchronization of the shock within the QRS complex and right ventricular effective refractory periods determined via the cardioverter remained constant over the follow-up period. VT was terminated on every occasion in nine patients and on eight of nine occasions in one patient. Tachycardia was accelerated on three of five occasions in one patient. Consistently effective cardioversion energy (0.2 to 2.0 J) increased modestly in four patients. We conclude that patients with inducible monomorphic VT usually have sustained VT with similar characteristics inducible over a period of time and cardioversion and sensing functions of the cardioverter remain relatively stable over time.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Noninvasive programmed stimulation in the setting of ventricular tachycardia catheter ablation;Journal of Cardiovascular Electrophysiology;2020-04-30

2. Prognostic value of noninvasive programmed stimulation in patients with implantable cardioverter defibrillator;Pacing and Clinical Electrophysiology;2018-10-24

3. Inappropriate Implantable Cardioverter-Defibrillator Therapy;Cardiac Electrophysiology Clinics;2009-12

4. Postinfarction Sustained Monomorphic Ventricular Tachycardia;Clinical Arrhythmology and Electrophysiology;2009

5. Programación del desfibrilador automático implantable;Revista Española de Cardiología Suplementos;2008-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3