Human right ventricular end-systolic pressure-volume relation defined by maximal elastance.

Author:

Brown K A1,Ditchey R V1

Affiliation:

1. Cardiology Unit, University of Vermont College of Medicine, Burlington.

Abstract

This study was undertaken to determine 1) whether a combined radionuclide-hemodynamic technique could define the right ventricular end-systolic pressure-volume relation (RV ESPVR) in the clinical setting, 2) whether the human RV ESPVR defined by maximal elastance is linear and responsive to inotropic interventions, and 3) whether more easily measured modifications of the ESPVR are reliable substitutes as an index of RV function. Eight patients with normal RV function were studied with simultaneous micromanometer RV pressure measurements and radionuclide ventriculography to construct RV pressure-volume loops. Data were collected at baseline and after at least two alterations in loading conditions with nitroglycerin, phenylephrine, or saline. End systole was defined by maximal elastance (E(t) = P(t)/[V(t) - V0]). Data were also obtained during administration of dobutamine in four patients and after atrial pacing tachycardia in one patient. The RV ESPVR defined by maximal elastance was highly linear (r = 0.988-0.999) throughout the range of pressures and volumes tested. Furthermore, the linear correlations were significantly higher (p less than 0.005), and the linear regression standard error of the estimate (SEE) was significantly lower (p less than 0.005) for the RV ESPVR defined by maximal elastance compared with modifications of the ESPVR with the ratio of pulmonary artery-dicrotic notch pressure or RV peak pressure to end-ejection volume. Dobutamine or atrial pacing tachycardia produced a leftward shift of the entire RV pressure-volume loop, and in each patient (five of five), the point of maximal elastance fell outside the 95% confidence interval defined by the baseline ESPVR. However, because of the larger SEE, the leftward shift with modifications of the ESPVR was not statistically significant in any patient by the pulmonary artery-dicrotic notch pressure: end-ejection volume ratio and was significant in only one of five patients by the RV peak pressure: end-ejection volume ratio (p less than 0.03). Therefore, it appears that the steady-state RV ESPVR defined by maximal elastance in patients with normal RV function is responsive to alterations in inotropic state and is more sensitive to alterations in RV function than the frequently used, more easily measured modifications of the RV ESPVR.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3