Overdrive suppression of conduction at the canine Purkinje-muscle junction.

Author:

Gilmour R F1,Davis J R1,Zipes D P1

Affiliation:

1. Krannert Institute of Cardiology, Indiana University School of Medicine, Indianapolis 46223.

Abstract

We have shown previously that overdrive suppression of conduction in depolarized His-Purkinje tissue requires conduction asymmetry. In this study we examined whether overdrive suppression of conduction can occur at the Purkinje-muscle junction, where natural asymmetry of conduction exists. Canine Purkinje-muscle preparations were superfused with hyperkalemic Tyrode's solution (KCl 8 to 12 mM), and action potentials were recorded from Purkinje, junctional, and muscle cells. Initially, the Purkinje fiber was paced at the shortest cycle length at which 1:1 anterograde Purkinje-muscle conduction occurred. The papillary muscle then was paced for 10 to 50 beats at shorter cycle lengths during which, because of conduction asymmetry at the Purkinje-muscle junction, 1:1 retrograde muscle-Purkinje conduction also occurred. After overdrive papillary muscle pacing, Purkinje fiber pacing at the same cycle length that previously resulted in 1:1 conduction now produced transient Purkinje-muscle conduction block (overdrive suppression of conduction). The degree and duration of overdrive suppression of conduction were proportional to the rate and duration of overdrive pacing. After overdrive pacing, Purkinje cell action potential amplitude and Vmax recovered within 300 msec, yet conduction block persisted for up to 7 sec. In contrast, excitability in papillary muscle cells near the Purkinje-muscle junction increased continuously after overdrive pacing. These data suggest that rapid activation of Purkinje cells during overdrive pacing was not required for overdrive suppression of conduction and that restoration of conduction after overdrive pacing was determined primarily by recovery of excitability in papillary muscle cells. Transient Purkinje-muscle conduction block after periods of rapid ventricular rates might account for overdrive-induced conduction disturbances normally attributed to bundle branch block.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference26 articles.

1. Artificial pacing of the human heart

2. Fisch C: Bundle branch block after ventricular tachycardia: a manifestation of "fatigue" or "overdrive suppression." J Am Coll Cardiol 3: 1562 1984

3. Differential effect of atrial and ventricular pacing in the induction of paroxysmal AV block in the ischemic His Purkinje system;El-Sherif N;Clin Res,1975

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3