Multiscale Motion Mapping

Author:

Sühling Michael1,Jansen Christian1,Arigovindan Muthuvel1,Buser Peter1,Marsch Stephan1,Unser Michael1,Hunziker Patrick1

Affiliation:

1. From the Swiss Federal Institute of Technology Lausanne (EPFL), Lausanne, Switzerland (M.S., M.A., M.U.), and the University Hospital Basel, Basel, Switzerland (C.J., P.B., S.M., P.H.).

Abstract

Background— Objective, quantitative, segmental noninvasive/bedside measurement of cardiac motion is highly desirable in cardiovascular medicine, but current technology suffers from significant drawbacks, such as subjectivity of conventional echocardiographic reading, angle dependence of tissue Doppler measurements, radiation exposure by computer tomography, and infrastructure requirements in MRI. We hypothesized that computer vision technology could represent a powerful new paradigm for quantification in echocardiography. Methods and Results— We present multiscale motion mapping, a novel computer vision technology that is based on mathematical image processing and that exploits echocardiographic information in a fashion similar to the human visual system. It allows Doppler- and border-independent determination of motion and deformation in echocardiograms at arbitrary locations. Correctness of the measurements was documented in synthetic echocardiograms and phantom experiments. Exploratory case studies demonstrated its usefulness in a series of complex motion analyses that included abnormal septal motion and analysis of myocardial twisting. Clinical applicability was shown in a consecutive series of echocardiograms, in which good feasibility, good correlation with expert rating, and good intraobserver and interobserver concordance were documented. Separate assessment of 2D displacement and deformation at the same location was successfully applied to elucidate paradoxical septal motion, a common clinical problem. Conclusions— This is the first clinical report of multiscale motion mapping, a novel approach to echocardiographic motion quantification. For the first time, full 2D echocardiographic assessment of both motion and deformation is shown to be feasible. Overcoming current limitations, this computer vision–based technique opens a new door to objective analysis of complex heart motion.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3