Heart Failure and the Risk of Shocks in Patients With Implantable Cardioverter Defibrillators

Author:

Whang William1,Mittleman Murray A.1,Rich David Q.1,Wang Paul J.1,Ruskin Jeremy N.1,Tofler Geoffrey H.1,Muller James E.1,Albert Christine M.1

Affiliation:

1. From the Cardiovascular Division, (W.W., J.N.R., J.E.M., C.M.A.) Massachusetts General Hospital, Cardiovascular Division (D.Q.R., M.A.M.), Beth Israel Deaconess Medical Center, and the Division of Preventive Medicine (C.M.A.), Brigham and Women’s Hospital, Harvard Medical School, Boston, Mass; Stanford University Medical Center (P.J.W.), Stanford, Calif; and the Royal North Shore Hospital (G.E.H.), Sydney, Australia.

Abstract

Background— Left ventricular ejection fraction (LVEF) predicts device discharges in patients with implantable cardioverter-defibrillators (ICDs). The relationship between severity of congestive heart failure (CHF) and ICD discharges is less clear. Methods and Results— We prospectively analyzed the association between CHF and risk of appropriate ICD discharges in the Triggers Of Ventricular Arrhythmias (TOVA) study, a cohort study of ICD patients conducted at 31 centers in the United States. Reported shocks were confirmed for sustained ventricular tachycardia (VT) or fibrillation (VF) by analysis of stored electrograms. Proportional hazards models included CHF categorized by New York Heart Association class. Baseline CHF was present among 502 (44%) of 1140 patients; 170 (34%) had class I, 230 (46%) had class II, 97 (19%) had class III, and only 5 (1%) had class IV symptoms. During median follow-up of 212 days, 92 patients experienced 1 or more appropriate ICD discharges. Class III CHF was associated in a statistically significantly manner with ICD discharge for VT/VF (hazard ratio 2.40, 95% CI 1.16 to 4.98), even with adjustment for LVEF. The combination of LVEF <0.20 and class III symptoms resulted in a particularly high risk of shocks for VT/VF (hazard ratio 3.90, 95% CI 1.28 to 11.92). Conclusions— Class III CHF, an easily accessible clinical measure, is an independent risk factor, along with LVEF, for ventricular arrhythmias that require shock therapy among ICD patients. Whether patients with class III CHF benefit to a greater degree from ICDs and whether aggressive treatment of CHF in ICD patients may prevent ventricular arrhythmias remains to be determined.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3