Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL)

Author:

Regar E.1,Serruys P.W.1,Bode C.1,Holubarsch C.1,Guermonprez J.L.1,Wijns W.1,Bartorelli A.1,Constantini C.1,Degertekin M.1,Tanabe K.1,Disco C.1,Wuelfert E.1,Morice M.C.1

Affiliation:

1. From Thoraxcenter, Rotterdam, the Netherlands (E.R., P.W.S., M.D., K.T.); Medizinische Universitätsklinik, Freiburg, Germany (C.B., C.H.); Hôpital Broussais, Paris, France (J.L.G.); Onze Lieve Vrouw Klinik, Aalst, Belgium (W.W.); Centro Cardiologico, Milano, Italy (A.B.); Clinico Cardiologico, Curitibana, Parana, Brasil (C.C.); Cardialysis BV, Rotterdam, the Netherlands (C.D.); Cordis Corporation, Waterloo, Belgium (E.W.); and L’Institut Cardiovasculaire Paris-Sud, Massy, France (M.C.M.).

Abstract

Background— Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, ≈40% of the vessels were small (<2.5 mm). The present study evaluates the relationship between angiographic outcome and vessel diameter for sirolimus-eluting stents. Methods and Results— Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into terciles according to their reference diameter (RD; stratum I, RD <2.36 mm; stratum II, RD 2.36 mm to 2.84 mm; stratum III, RD >2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01±0.25 versus 0.80±0.43 mm in stratum I, 0.01±0.38 versus 0.88±0.57 mm in stratum II, and −0.06±0.35 versus 0.74±0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Δ −0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, ΔMLD <−0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation ( P <0.001) and postprocedural MLD ( P = 0.008). Conclusions— Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 187 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3