Early Clinical Results of the Telemetric Adjustable Pulmonary Artery Banding FloWatch-PAB

Author:

Bonnet Damien1,Corno Antonio F.1,Sidi Daniel1,Sekarski Nicole1,Beghetti Maurice1,Schulze-Neick Ingram1,Fasnacht Margrit1,Le Bret Emmanuel1,Kalangos Afksendyios1,Vouhé Pascal R.1,von Segesser Ludwig K.1

Affiliation:

1. From the Pediatric Cardiology (D.B., D.S., E.L., P.R.V.), Hôpital Necker Enfants Malades, Paris, France; Centre Hospitalier Universitaire Vaudois (A.F.C., N.S., L.K.V), Lausanne, Switzerland; Cardiology Unit (M.B., A.K.), Hôpital des Enfants, Department of Paediatrics (I.S.N), Geneva, Switzerland; Abteilung fur Angeborene Herzfehler, Deutsches Herzzentrum Berlin, Berlin, Germany; Oberärztin Kardiologie Universitätskinderklinik (M.F.), Zürich, Switzerland.

Abstract

Background— Adjustment of pulmonary artery banding (PAB) may be a challenging procedure in complex congenital heart defects. Whatever the technique used, subsequent re-operations are frequently needed to control the pulmonary blood flow or pressures. Objective— To report the efficacy of a new telemetric adjustable PAB (FloWatch-PAB) operated with the help of an external control unit that transmits to the implant energy and commands to further narrow or release the pulmonary artery using radiofrequency waves. Methods and Results— In a multicenter, prospective, nonrandomized, single-arm clinical investigation, 13 children (median age, 4.5 months; range, 6 days to 11 years; median weight, 4.2 kg; range, 3.1 to 27kg) underwent implantation of the FloWatch-PAB through median sternotomy in 8 and left thoracotomy in 5. The diagnosis was multiple ventricular septal (VSD) defects with complex anatomy in 3, single ventricle without pulmonary stenosis in 2, VSD with elevated pulmonary vascular resistance (PVR) in 2, atrio-ventricular canal (AVC) with elevated pulmonary vascular resistance in 1, AVC with diminutive right ventricle in 1, complex transposition of the great arteries in 3, and pulmonary atresia with complex pulmonary arteries anatomy in 1. All patients had normosystemic systolic pulmonary artery pressure. Additional procedures were performed in 7: atrial septectomy in 2, double aortic arch division in 1, patent ductus arteriosus ligation in 2, and coarctation repair in 2. There were no early or late deaths or device-related complications in a mean follow-up of 24 weeks (range, 18 to 42 weeks). A mean of 5.8 telemetric regulations per patient using the FloWatch-PAB were required to adjust the tightening of the PAB to the clinical needs (narrowing 74%, releasing 26%). At last follow-up, systolic pulmonary artery pressure was within normal range in all patients but 1. Systemic oxygen saturation demonstrated optimal regulation of the pulmonary blood flow in all according to each specific defect. Four patients were successfully corrected (VSD closure, AVSD repair, and 2 arterial switches with VSD closure). The device was easily removed and the pulmonary artery re-expanded spontaneously. Conclusion— This new device is safe and allows optimal adjustment of PAB in complex heart defects. In children requiring PAB, the use of this technology can obviate the need for early re-operations and appears to be a valuable option in the panel of surgical alternatives for selected infants.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3