Paclitaxel Balloon Coating, a Novel Method for Prevention and Therapy of Restenosis

Author:

Scheller Bruno1,Speck Ulrich1,Abramjuk Claudia1,Bernhardt Ulrich1,Böhm Michael1,Nickenig Georg1

Affiliation:

1. From the Department of Internal Medicine III—Cardiology/Angiology (B.S., M.B., G.N.), University of Saarland, Homburg/Saar, Germany; the Department of Radiology (U.S., C.A.), Charité University Hospital, Berlin, Germany; and Anakat GmbH (U.B.), Berlin, Germany.

Abstract

Background— Drug-eluting stents have shown promising antirestenotic effects in clinical trials. Non–stent-based local delivery of antiproliferative drugs may offer additional flexibility and also reach vessel areas beyond the immediate stent coverage. The aim of the present study was to evaluate a novel method of local drug delivery based on angioplasty balloons. Methods and Results— Stainless steel stents (n=40; diameter, 3.0 to 3.5 mm; length, 18 mm) were implanted in the left anterior descending and circumflex coronary arteries of domestic pigs. Both conventional uncoated and 3 different types of paclitaxel-coated, percutaneous transluminal coronary angioplasty balloons (contact with vessel wall for 1 minute) were used. No difference in short-term tolerance between coated and uncoated balloons and no signs of thrombotic events were observed. Quantitative angiography and histomorphometry of the stented arteries asserted the statistical equality of the baseline parameters between the control and the 3 treatment groups. Paclitaxel balloon coating led to a marked, dose-dependent reduction of parameters characterizing in-stent restenosis (reduction of neointimal area up to 63%). Despite the marked reduction in neointimal proliferation, endothelialization of stent struts was present in all samples. There was no evidence of a significant inflammatory response in the neighborhood of the stent struts. Conclusions— Paclitaxel balloon coating is safe, and it effectively inhibits restenosis after coronary angioplasty with stent implantation in the porcine model. The degree of reduction in neointimal formation was comparable to that achieved with drug-eluting stents.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司