Distal Protection With a Filter Device During Coronary Stenting in Patients With Stable and Unstable Angina

Author:

Angelini Annalisa1,Rubartelli Paolo1,Mistrorigo Flavio1,Della Barbera Mila1,Abbadessa Francesco1,Vischi Massimo1,Thiene Gaetano1,Chierchia Sergio1

Affiliation:

1. From the Department of Pathology, University of Padua Medical School, Padua (A.A., F.M., M.D.B., G.T.), and the Cardiology Division, San Martino Hospital, Genoa (P.R., F.A., M.V., S.C.), Italy.

Abstract

Background— Filter protection after percutaneous coronary intervention (PCI) is now available to prevent distal embolization. The aims of this study were (1) to evaluate the microembolization phenomenon during procedures of stent implantation in native coronary arteries of patients with stable and unstable angina, (2) to assess the amount and characteristics of the debris captured by the Angioguard, and (3) to investigate the relation between clinical and angiographic variables and pathological data. Methods and Results— Elective coronary stenting with the use of a protective filter was attempted in 39 consecutive coronary artery lesions with >60% stenosis (mean, 67.6±8.79%). Debris was present in 75.6% of the filters. Particle size ranged from 47.16 to 2503.48 μm (mean, 518.83±319.61 μm) in the major axis. Particles >300 μm were found in 24 of 28 filters with debris (85.7%), and particles >1000 μm were present in 10 of 28 filters (35.7%). Patients with unstable angina had greater particles (mean maximum longitudinal diameter, 1098.33±714.3 μm) than those with stable angina (412.91±453 μm; P <0.001). The presence of unstable angina (OR, 65; CI, 1.2 to 3420; P =0.03) and age >67 years (OR, 42; CI, 1 to 1698; P =0.04) were found to be the only independent predictors of embolic particle size. Conclusions— By limiting embolization, protective devices may prevent a number of potentially unfavorable events, thereby improving outcome. Our data support the use of these devices, especially in lesions with higher embolic potential, such as those occurring in older patients and in those with unstable angina.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 81 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3