Reverse Remodeling of Sinus Node Function After Catheter Ablation of Atrial Fibrillation in Patients With Prolonged Sinus Pauses

Author:

Hocini Mélèze1,Sanders Prashanthan1,Deisenhofer Isabel1,Jaïs Pierre1,Hsu Li-Fern1,Scavée Christophe1,Weerasoriya Rukshen1,Raybaud Florence1,Macle Laurent1,Shah Dipen C.1,Garrigue Stéphane1,Le Metayer Philippe1,Clémenty Jacques1,Haïssaguerre Michel1

Affiliation:

1. From Hôpital Cardiologique du Haut-Lévêque, Bordeaux, France.

Abstract

Background— Symptomatic prolonged sinus pauses on termination of atrial fibrillation (AF) are an indication for pacemaker implantation. We evaluated sinus node function and clinical outcome in patients with prolonged sinus pauses on termination of arrhythmia who underwent ablation of paroxysmal AF. Methods and Results— Twenty patients with paroxysmal AF and prolonged sinus pauses (≥3 seconds) on termination of AF underwent ablation between May 1995 and November 2002. Patients with sinus pauses independent of episodes of AF were excluded from the analysis. The procedure included pulmonary vein and linear atrial ablation. After ablation, sinus node function was assessed during the first week and at 1, 3, and 6 months, by 24-hour ambulatory monitoring to determine the mean heart rate and heart rate range, and by exercise testing to determine the maximal heart rate. Corrected sinus node recovery time was determined at the completion of ablation and at 24.0±11.3 months at 600 and 400 ms. After AF ablation, there was a significant improvement of sinus node function, with an increase in the mean heart rate ( P =0.001), maximal heart rate ( P <0.0001), and heart rate range ( P <0.0001). The corrected sinus node recovery time decreased in all patients evaluated at 600 ms ( P =0.016) and 400 ms ( P =0.019). At 26.0±17.6 months, 18 patients (85%) had no recurrence of AF (in the absence of medication), with no symptoms attributable to bradycardia or sinus pauses on ambulatory monitoring. Two patients had infrequent episodes of AF, 1 requiring pacemaker implantation. Conclusion— Prolonged sinus pauses after paroxysms of AF may result from depression of sinus node function that can be eliminated by curative ablation of AF. This is accompanied by improvement in parameters of sinus node function, suggesting reverse remodeling of the sinus node.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 164 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3