Impact of Myocardial Ischemia and Reperfusion on Ventricular Defibrillation Patterns, Energy Requirements, and Detection of Recovery

Author:

Qin Hao1,Walcott Gregory P.1,Killingsworth Cheryl R.1,Rollins Dennis L.1,Smith William M.1,Ideker Raymond E.1

Affiliation:

1. From the Departments of Physiology and Biophysics, Medicine, and Biomedical Engineering, University of Alabama at Birmingham.

Abstract

Background Shocks that have defibrillated spontaneous ventricular fibrillation (VF) during acute ischemia or reperfusion may seem to have failed if VF recurs before the ECG amplifier recovers after shock. This could explain why the defibrillation threshold (DFT) for spontaneous VF appears markedly higher than for electrically induced VF. Methods and Results The DFT for electrically induced VF (E-DFT) was determined in 15 pigs before ischemia, followed by left anterior ascending or left circumflex artery occlusion. VF was electrically induced 20 minutes after occlusion, followed 5 minutes later by reperfusion. Whether spontaneous or electrically induced, VF during occlusion or reperfusion was treated with up to 3 shocks at 1.5×E-DFT. If all 3 shocks failed, shock strength was increased. Thirty minutes after reperfusion, the other artery was occluded and the protocol was repeated. Defibrillation was considered successful if postshock sinus/idioventricular rhythm was present for ≥30 seconds. VF recurring within 30 seconds after the shock was considered immediate or delayed if the first postshock activation complex in a rapidly restored ECG recording was VF or sinus/idioventricular rhythm, respectively. Defibrillation efficacy at 1.5×E-DFT was significantly higher for electrically induced ischemic VF (76%) than for spontaneous VF (31%). The incidence of delayed recurrence after electrically induced nonischemic (3%) or ischemic (20%) VF was significantly lower than after spontaneous VF (75%). Mean VF recurrence time after spontaneous VF was 4.6±5.3 seconds. Conclusions Spontaneous VF can be halted by a shock but then quickly restart before a standard ECG amplifier has recovered from postshock saturation, making it appear that the shock failed.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3