Abstract

Background In patients with complex pulmonary stenosis or atresia, a detailed delineation of all sources of pulmonary blood supply is necessary for planning surgical and transcatheter procedures and usually requires diagnostic cardiac catheterization. The goals of this study were to determine whether gadolinium-enhanced 3D magnetic resonance angiography (MRA) can provide a noninvasive alternative to diagnostic catheterization and to compare MRA and x-ray angiography measurements of pulmonary arteries and aortopulmonary collaterals (APCs). Methods and Results Thirty-two patients with pulmonary stenosis or atresia (median age: 4.7 years, range: 1 day to 46.9 years) underwent both MRA and cardiac catheterization (median time: 1 month). Diagnoses included tetralogy of Fallot (TOF) with pulmonary atresia (n=13), TOF with pulmonary stenosis (n=4), post-Fontan palliation (n=5), and other complex congenital heart disease (n=10). Compared with catheterization and surgical observations, MRA had a 100% sensitivity and specificity for the diagnosis of main (n=10) and branch pulmonary artery (PA) stenosis or hypoplasia (n=38), as well as absent (n=5) or discontinuous (n=4) branch PAs. All 48 major APCs diagnosed by catheterization were correctly diagnosed by MRA. Three additional APCs were diagnosed by MRA but not by catheterization. The mean difference between MRA and catheterization measurements of 33 pulmonary vessel diameters was 0.5±1.5 mm, with a mean interobserver difference of 0.4±1.5 mm. Conclusions Gadolinium-enhanced 3D MRA is a fast and accurate technique for delineation of all sources of pulmonary blood supply in patients with complex pulmonary stenosis and atresia and can be considered a noninvasive alternative to diagnostic catheterization with x-ray angiography.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 210 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3