Myocardial First-Pass Perfusion Magnetic Resonance Imaging

Author:

Wolff S.D.1,Schwitter J.1,Coulden R.1,Friedrich M.G.1,Bluemke D.A.1,Biederman R.W.1,Martin E.T.1,Lansky A.J.1,Kashanian F.1,Foo T.K.F.1,Licato P.E.1,Comeau C.R.1

Affiliation:

1. From the Cardiovascular Research Foundation and Lenox Hill Hospital, New York, NY (S.D.W., A.J.L., C.R.C.); University Hospital of Zurich, Zurich, Switzerland (J.S.); Papworth and Addenbrooke’s Hospitals, Cambridge, UK (R.C.); Franz-Volhard Klinik, Berlin-Buch, Germany (M.G.F.); Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Md (D.A.B.); Allegheny General Hospital, Pittsburgh, Pa (R.W.B.); Oklahoma Heart Institute, Tulsa (E.T.M.); Berlex...

Abstract

Background— MRI can identify patients with obstructive coronary artery disease by imaging the left ventricular myocardium during a first-pass contrast bolus in the presence and absence of pharmacologically induced myocardial hyperemia. The purpose of this multicenter dose-ranging study was to determine the minimally efficacious dose of gadopentetate dimeglumine injection (Magnevist Injection; Berlex Laboratories) for detecting obstructive coronary artery disease. Method and Results— A total of 99 patients scheduled for coronary artery catheterization as part of their clinical evaluation were enrolled in this study. Patients were randomized to 1 of 3 doses of gadopentate dimeglumine: 0.05, 0.10, or 0.15 mmol/kg. First-pass perfusion imaging was performed during hyperemia (induced by a 4-minute infusion of adenosine at a rate of 140 μg · kg −1 · min −1 ) and then again in the absence of adenosine with otherwise identical imaging parameters and the same contrast dose. Perfusion defects were evaluated subjectively by 4 blinded reviewers. Receiver-operating curve analysis showed that the areas under the receiver-operating curve were 0.90, 0.72, and 0.83 for the low-, medium-, and high-contrast doses, respectively, compared with quantitative coronary angiography (diameter stenosis ≥70%). For the low-dose group, mean sensitivity was 93±0%, mean specificity was 75±7%, and mean accuracy was 85±3%. Conclusions— First-pass perfusion MRI is a safe and accurate test for identifying patients with obstructive coronary artery disease. A low dose of 0.05 mmol/kg gadopentetate dimeglumine is at least as efficacious as higher doses.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 195 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3