Incomplete Resolution of ST-Segment Elevation Is a Marker of Transient Microcirculatory Dysfunction After Stenting for Acute Myocardial Infarction

Author:

Feldman Laurent J.1,Coste Pierre1,Furber Alain1,Dupouy Patrick1,Slama Michel S.1,Monassier Jean-Pierre1,Tron Christophe1,Lafont Antoine1,Faraggi Marc1,Le Guludec Dominique1,Dubois-Randé Jean-Luc1,Steg P. Gabriel1

Affiliation:

1. From CHU Bichat AP-HP, Paris, France (L.J.F., M.F., D.L.G., P.G.S.); CHU Haut-Lévêque, Bordeaux, France (P.C.); CHU Angers, France (A.F.); CHU Henri Mondor, Créteil, France (P.D., J.-L.D.R.); CHU Antoine Béclère, Clamart, France (M.S.S.); Hôpital Emile Muller, Mulhouse, France (J.-P.M.); CHU Charles Nicolle, Rouen, France (C.T.); and Hôpital Européen Georges Pompidou, Paris, France (A.L.).

Abstract

Background— Incomplete ST-segment resolution (STR) after successful primary angioplasty for acute myocardial infarction (AMI) is associated with a poor prognosis. We used intracoronary Doppler velocimetry to investigate whether incomplete STR after primary angioplasty is a marker of severe microcirculatory dysfunction. Methods and Results— Fifty patients with ≤12-hour AMI underwent successful primary angioplasty and systematic stenting with a Doppler guidewire. Patients with incomplete (<50%) STR 60 minutes after TIMI 3 flow was restored had flow velocity features suggestive of severe microcirculatory dysfunction, including a higher incidence of early systolic retrograde flow (41% versus 9%, P =0.007) and lower coronary flow velocity reserve (CVR, 1.3 versus 1.6, P <0.001). CVR improved immediately after stenting in patients with ≥50% STR but not in patients with <50% STR. There was a significant correlation between STR and poststent CVR. At 3 months, CVR was similar in patients with <50% and ≥50% STR. However, left ventriculography indicated lower global (42% versus 55%, P =0.001) and regional (16% versus 20%, P =0.03) left ventricular ejection fractions and 201 Tl rest-redistribution scintigraphy indicated a larger infarct size (34% versus 16% 201 Tl defect, P =0.007) in patients with <50% STR. Conclusions— After successful primary angioplasty with systematic stenting, <50% STR is a marker of severe albeit transient microcirculatory dysfunction in patients with AMI and is associated with more extensive myocardial damage.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3