Quantitative 3-Dimensional Echocardiography for Accurate and Rapid Cardiac Phenotype Characterization in Mice

Author:

Dawson Dana1,Lygate Craig A.1,Saunders James1,Schneider Jürgen E.1,Ye Xujiong1,Hulbert Karen1,Noble J. Alison1,Neubauer Stefan1

Affiliation:

1. From the Departments of Cardiovascular Medicine (D.D., C.A.G., J.E.S., K.H., S.N.) and Engineering Science (J.S., X.Y., J.A.N.), University of Oxford, Oxford, England.

Abstract

Background— Insufficient techniques exist for rapid and reliable phenotype characterization of genetically manipulated mouse models of cardiac dysfunction. We developed a new, robust, 3-dimensional echocardiography (3D-echo) technique and hypothesized that this 3D-echo technique is as accurate as magnetic resonance imaging (MRI) and histology for assessment of left ventricular (LV) volume, ejection fraction, mass, and infarct size in normal and chronically infarcted mice. Methods and Results— Using a high-frequency, 7/15-MHz, linear-array ultrasound transducer, we acquired ECG and respiratory-gated, 500-μm consecutive short-axis slices of the murine heart within 4 minutes. The short-axis movies were reassembled off-line in a 3D matrix by using the measured platform locations to position each slice in 3D. Epicardial and endocardial heart contours were manually traced, and a B-spline surface was fitted to the delineated image curves to reconstruct the heart volumes. Excellent correlations were obtained between 3D-echo and MRI for LV end-systolic volumes ( r =0.99, P <0.0001), LV end-diastolic volumes ( r =0.99, P <0.0001), ejection fraction ( r =0.99, P <0.0001), LV mass ( r =0.94, P <0.0019), and infarct size ( r =0.98, P <0.0001). Also, excellent correlations were found between the 3D-echo–derived LV mass and necropsy LV mass in normal mice ( r =0.99, P <0.0001), as well as for 3D-echo–derived infarct size and histologically determined infarct size ( r =0.99, P <0.0001) in mice with chronic heart failure. Bland-Altman analysis showed excellent limits of agreement between techniques for all measured parameters. Conclusion— This new, fast, and highly reproducible 3D-echo technique should be of widespread applicability for high-throughput murine cardiac phenotyping studies.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 96 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3