Ultrasonic Characterization of the Pulmonary Venous Wall

Author:

Cabrera José Angel1,Sánchez-Quintana Damián1,Farré Jerónimo1,Navarro Felipe1,Rubio José Manuel1,Cabestrero Fernando1,Anderson Robert H.1,Ho Siew Yen1

Affiliation:

1. From Servicio de Cardiología (J.A.C., J.F., F.N., J.M.R., F.C.), Fundación Jiménez Díaz, Universidad Autónoma, Madrid; Departamento de Anatomía Humana (D.S.Q.), Facultad de Medicina, Universidad de Extremadura, Badajoz, Spain; Cardiac Unit (R.H.A.), Institute of Child Health, University College London; and Paediatrics (S.Y.H.), National Heart and Lung Institute, Imperial College, London, UK.

Abstract

Background— Pulmonary vein isolation with radiofrequency catheter ablation techniques is used to prevent recurrences of human atrial fibrillation. Visualization of the architecture at the venoatrial junction could be crucial for these ablative techniques. Our study assesses the potential for intravascular ultrasound to provide this information. Methods and Results— We retrieved 32 pulmonary veins from 8 patients dying from noncardiac causes. We obtained cross-sectional intravascular ultrasound (IVUS) images with a 3.2F, 30-MHz ultrasound catheter at intervals on each vein. Histological cross-sections at the intervals allowed comparisons with ultrasonic images. The pulmonary venous wall at the venoatrial junction revealed a 3-layered ultrasonic pattern. The inner echogenic layer represents both endothelium and connective tissue of the media (mean maximal thickness, 1.4±0.3 mm). The middle hypoechogenic stratum corresponds to the sleeves of left atrial myocardium surrounding the external aspect of the venous media. This layer was thickest at the venoatrial junction (mean maximal thickness, 2.6±0.8 mm) and decreased toward the lung hilum. The outer echodense layer corresponds to fibro-fatty adventitial tissue (mean maximal thickness, 2.15±0.36 mm). We found a close agreement among the IVUS and histological measurements for maximal luminal diameter (mean difference, −0.12±1.3 mm) and maximal muscular thickness (mean difference, 0.17±0.13 mm) using the Bland and Altman method. Conclusions— Our experimental study demonstrates for the first time that IVUS images of the pulmonary veins can provide information on the distal limits and thickness of the myocardial sleeves and can be a valuable tool to help accurate targeting during ablative procedures.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3