Assessing Myocardial Viability and Infarct Transmurality With Left Ventricular Electromechanical Mapping in Patients With Stable Coronary Artery Disease

Author:

Perin Emerson C.1,Silva Guilherme V.1,Sarmento-Leite Rogerio1,Sousa Andre L.S.1,Howell Marcus1,Muthupillai Raja1,Lambert Brenda1,Vaughn William K.1,Flamm Scott D.1

Affiliation:

1. From the Departments of Adult Cardiology and Radiology, Texas Heart Institute/St Luke’s Episcopal Hospital and Baylor College of Medicine, Houston, Tex, and Philips Medical Systems, North America, Bothell, Wash.

Abstract

Background— This study was designed to define myocardial viability and establish practical cut-off values for differentiating normal myocardial tissue from subendocardial and transmural scar tissue by using electromechanical mapping (EMM). We validated our results by delayed-enhancement cardiac MRI (DE-MRI). Methods and Results— We prospectively studied 15 ambulatory patients with stable coronary disease who were candidates for cardiac catheterization. Within 48 hours of EMM, DE-MRI was performed. Using EMM software, we created a bull’s eye precisely matched to that generated by DE-MRI. Segment by segment, we compared the MRI results to the corresponding unipolar voltage value for that same segment in the EMM bull’s eye. Of 300 total segments, 275 were compared. The segments were divided into normal (n=211), subendocardial scar (n=49), and transmural scar (n=15). We found that subendocardial (6.8±2.9 mV) and transmural (4.6±1.9 mV) scar segments had significantly less unipolar voltage than normal (11.6±4.5 mV) segments ( P <0.05 for each comparison). When normal myocardium was compared with myocardium with subendocardial scar, the threshold for differentiating between the two areas was 7.9 mV (sensitivity, 80%; specificity, 80%). Comparison of normal tissue to transmural scar yielded a threshold of 6.9 mV (sensitivity, 93%; specificity, 88%). Conclusions— Our results demonstrate that normal myocardium can be accurately distinguished from myocardium with subendocardial or transmural infarcts on the basis of unipolar voltage values obtained through EMM. This is the first study to validate these results by using cardiac DE-MRI in humans.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference45 articles.

Cited by 107 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3