Ultrasound Imaging of Acute Cardiac Transplant Rejection With Microbubbles Targeted to Intercellular Adhesion Molecule-1

Author:

Weller Gregory E.R.1,Lu Erxiong1,Csikari Melissa M.1,Klibanov Alexander L.1,Fischer David1,Wagner William R.1,Villanueva Flordeliza S.1

Affiliation:

1. From the Department of Bioengineering (G.E.R.W., W.R.W.) and McGowan Institute for Regenerative Medicine (G.E.R.W., W.R.W.), University of Pittsburgh, Pa; Cardiovascular Institute (E.L., M.M.C., D.F., F.S.V.), University of Pittsburgh School of Medicine, Pa; and Cardiovascular Imaging Center (A.L.K.), University of Virginia, Charlottesville, Va.

Abstract

Background— Noninvasive techniques for detecting acute cardiac transplant rejection are limited. We hypothesized that ultrasound contrast microbubbles targeted to the endothelial cell (EC) inflammatory marker intercellular adhesion molecule-1 (ICAM-1) would selectively bind to rejecting versus nonrejecting myocardium and that myocardial contrast echocardiography can therefore detect acute rejection. Methods and Results— Lipid-based microbubbles were conjugated to anti-rat ICAM-1 (MB ICAM ) or isotype control antibody (MB Control ). In vitro MB ICAM adhesion to cultured rat ECs, as assessed in a parallel plate flow apparatus, was greater to inflammatory versus normal ECs (11±3 versus 3±2 microbubbles/EC, P <0.005). In vivo abdominal heterotopic heart transplantation was performed in rats (rejection group: Brown Norway to Lewis strain; control group: Lewis to Lewis or Brown Norway to Brown Norway). Triggered myocardial contrast echocardiography was performed during intravenous MB ICAM or MB Control (2.5×10 6 ) injection on postoperative day 5. Myocardial videointensity from adhered MB ICAM was significantly higher in rejecting (n=8) versus control (n=7) rats (10±4 versus 1±4 U, P =0.01). Postmortem histology showed normal myocardium in control rats, whereas allograft myocardium demonstrated grade III to IV rejection and strong immunohistochemical ICAM-1 staining. Conclusions— Preferential adherence of ICAM-1-targeted microbubbles to rejecting versus nonrejecting rat cardiac transplant myocardium can be detected ultrasonically. Targeted microbubbles may thus offer a noninvasive ultrasound imaging technique for the detection of acute cardiac transplant rejection and other processes characterized by endothelial dysfunction.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 223 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3