Abstract
Residual solvents are organic volatile impurities that can occur in the manufacture of Active Pharmaceutical Ingredients (APIs). Residual solvents analysis in pharmaceutical products is necessary not only because of they represent a potential risk for human health due to their toxicity and their undesirables side effects, but also because they may affect the physicochemical proprieties of pharmaceutical product. The main objective of this work was to analysis 29 residual solvents-impurities by Head Space Gas Chromatography with Flame Ionization Detector (HS-GC-FID) in seven samples of Ciprofloxacin Hydrochloride API, collected from seven pharmaceutical industries installed in Algeria. The GC was equipped with a flame-ionization detector and silica column coated with 1.8 µm layer of phase G43. The carrier gas was helium with a linear velocity of 35 cm/s and a split ratio of 1:5. The column temperature was 40 °C then it rised to 240 °C. The injection temperature was 140 °C and that of detector was 250 °C. Twenty-nine organic solvents belong to classes 1 and 2 were analyzed in seven samples of Ciprofloxacin Hydrochloride API whose control is mandatory because of their carcinogenic and intrinsic toxicity. Only five solvents were identified wich are Hexane, Toluene, Acetonitrile, Methanol and Dichloromethane in the different samples. All samples collected satisfied the test of identification, so, the confirmation and the quantification procedures weren’t realized. The HS-GC-FID technique used showed that the identified solvents differ from one sample to another of the same molecule. This showed that manufacturers didn’t often use the same solvents to produce the same API, which justifies that residual organic solvent tests weren’t usually mentioned in the specific monographs.
Subject
General Pharmacology, Toxicology and Pharmaceutics
Reference21 articles.
1. [1] Goodfellow K. The Analysis of Residual Solvents in Pharmaceuticals using Headspace GC. Reading Scientific Services 2018 :01-02.
2. [2] Nacham O, Ho TD, Anderson JL, Webster GK. Use of ionic liquids as headspace gas chromatography diluents for the analysis of residual solvents in pharmaceuticals. J Pharm Biomed Anal 2017,145:879-886.
3. [3] ICH Harmonized Guideline. Impurities: Guideline for Residual Solvents Q3C(R6), International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use. 2016: 3-21.
4. [4] Mirmoghaddam M, Kaykhaii M, Yahyavi H. Recent developments in the determination of residual solvents in pharmaceutical products by microextraction methods. Anal Methods 2015, 7: 8511-8523.
5. [5] B’Hymer C. Residual solvent testing: a review of gas-chromatographic and alternative techniques. Pharm Res 2003, 20(3):337-44.