In-situ measurements of magmatic volatile elements, F, S, and Cl, by electron microprobe, secondary ion mass spectrometry, and heavy ion elastic recoil detection analysis

Author:

Rose-Koga Estelle F.12,Koga Kenneth T.13,Devidal Jean-Luc1,Shimizu Nobumichi4,Le Voyer Marion5,Dalou Celia6,Döbeli Max7

Affiliation:

1. Université Clermont Auvergne, CNRS UMR6524, IRD, OPGC, Laboratoire Magmas et Volcans, F-63000 Clermont-Ferrand, France

2. ‡ Special collection papers can be found online at http://www.minsocam.org/MSA/AmMin/special-collections.html.

3. † Orcid 0000-0002-0862-6804.

4. Department of Geology and Geophysics, Woods Hole Oceanographic Institution, Massachusetts 02543, U.S.A.

5. Smithsonian Institution, National Museum of Natural History, PO Box 37012, MRC 119, Washington, D.C. 20013, U.S.A.

6. Centre de Recherches Pétrographiques et Géochimiques, UMR7358, CNRS—Université de Lorraine, BP20, 54501 Vandoeuvre-lès-Nancy Cedex, France

7. Laboratory for Ion Beam Physics, ETH Zürich, 8093 Zürich, Switzerland

Abstract

Abstract Electron probe and ion probe are the two most used instruments for in situ analysis of halogens in geological materials. The comparison of these two methods on widely distributed glass standards (example: MPI-DING glasses, Jochum et al., G-cubed, 2006) provides a basis for establishing laboratory method, independent geochemical data sets for these elements. We report analyses of F, S, and Cl concentrations in three geological glass samples (EPMA) and 10 referenced standards (EPMA and SIMS). Furthermore, F and Cl absolute abundances have been determined independently for three of the standards (KL2-G, ATHO-G, and KE12), via heavy ion elastic recoil detection analysis (HIERDA), to certify the accuracy of the cross-calibration EPMA-SIMS. The detection limits for EPMA are a 150 μg·g-1 for F, 20 μg·g-1 for S and Cl, and for SIMS < 48 μg·g-1 for F, < 3 μg·g-1 for S, and <19 μg·g-1 for Cl. On SiO2-rich glass-standards, F and Cl measurements by HIERDA highlight a weak matrix effect during SIMS analysis of F and Cl. With the HIERDA independently measured value, we therefore propose an alternative calibration function to empirically correct this matrix effect on the SIMS measurements of F, S, and Cl.

Publisher

Mineralogical Society of America

Subject

Geochemistry and Petrology,Geophysics

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3