Affiliation:
1. Department of Mechanical Engineering, NIT Silchar, Assam (INDIA)
Abstract
Savonius vertical axis wind turbines (VAWT) have advantages over horizontal axis wind turbines (HAWT), such as simple construction, acceptance of wind from any direction without orientation, self-starting, inexpensive etc. These advantages make it a viable proposition for small-scale applications in developing countries. In spite of the above advantages, VAWT are not gaining popularity mainly because of their poor efficiency. Hence, a three-bucket Savonius model rotor, having 8 cm bucket diameter and 20 cm height, was designed, fabricated, and tested in a sub-sonic wind tunnel. Provisions for variations of ‘blade’ overlap were included. Experiments were conducted for overlap conditions in the range of 16% to 35%. From the experimental investigations, power-coefficients (Cp) were calculated with and without blockage correction factors for tunnel interference. In both analyses, the power-coefficient increased if there was overlap, with an optimum value at 20% overlap of 47% without blockage correction, and 38% with blockage correction.
Subject
Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment
Cited by
40 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献